D9 USB LED: loose contact reflowed, now lights correctly
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
@@ -249,18 +249,17 @@ schematic changes.
|
|||||||
OVLO divider off 12V_RAW, R_top ≈ 1.1 M / R_bottom ≈ 100 k → trip ~15 V.
|
OVLO divider off 12V_RAW, R_top ≈ 1.1 M / R_bottom ≈ 100 k → trip ~15 V.
|
||||||
See REVIEW.md eFuse entry. Bench workaround: feed 12 V onto 12V_EXI (C65+ /
|
See REVIEW.md eFuse entry. Bench workaround: feed 12 V onto 12V_EXI (C65+ /
|
||||||
U3 VIN) to bypass it. This must be fixed before any V2.1 fab order.
|
U3 VIN) to bypass it. This must be fixed before any V2.1 fab order.
|
||||||
- [ ] **D9 "USB" LED dark — OPEN SOLDER JOINT on its anode pad (found at
|
- [x] **D9 "USB" LED dark — OPEN SOLDER JOINT on its anode pad — FIXED by
|
||||||
bring-up 2026-09-30). Assembly defect on this unit, NOT a design bug.**
|
reflow 2026-09-30. Assembly defect on this unit, NOT a design bug.**
|
||||||
Symptom: D9 never lights, on USB-only or GC power. Measured 3V3 on the
|
Symptom: D9 never lights, on USB-only or GC power. Measured 3V3 on the
|
||||||
anode-side pad and 0 V on the cathode with the LED dark — i.e. the full
|
anode-side pad and 0 V on the cathode with the LED dark — i.e. the full
|
||||||
rail standing across it, so no current and no drop across R42 (if D9 were
|
rail standing across it, so no current and no drop across R42 (if D9 were
|
||||||
conducting the anode would sit at Vf ≈ 2 V). Touching the anode pad with a
|
conducting the anode would sit at Vf ≈ 2 V). Touching the anode pad with a
|
||||||
meter probe makes it light at full brightness: the probe pressure closes
|
meter probe makes it light at full brightness: the probe pressure closes
|
||||||
the joint. So Q2 (S8550 PNP) and R42 are fine and the LED itself is fine —
|
the joint. So Q2 (S8550 PNP) and R42 are fine and the LED itself is fine —
|
||||||
the terminal is sitting on the pad without wetting it. **Fix: flux +
|
the terminal was sitting on the pad without wetting it. **Reflowed —
|
||||||
reflow D9's anode pad** (and R42's pad on the same net, `Net-(D9-A)`,
|
D9 now lights correctly.** Cosmetic indicator only; never affected the
|
||||||
while the iron is there). Cosmetic indicator only; does not affect the
|
power mux, which works (GC/USB handover verified via D8 + rails).
|
||||||
power mux, which is working (GC/USB handover verified via D8 + rails).
|
|
||||||
Footprint is not suspect — D6/D8/D12 are the same reverse-mount part
|
Footprint is not suspect — D6/D8/D12 are the same reverse-mount part
|
||||||
(Everlight 24-21, C2980185) and all three light correctly.
|
(Everlight 24-21, C2980185) and all three light correctly.
|
||||||
- [ ] **12 V inrush limiter (U13 TPS25961 eFuse) — SCHEMATIC DONE 2026-07-31**,
|
- [ ] **12 V inrush limiter (U13 TPS25961 eFuse) — SCHEMATIC DONE 2026-07-31**,
|
||||||
|
|||||||
Reference in New Issue
Block a user