sim: make the EXI clock rate configurable; default was 8x too slow
bba_top derived its EXI clock from HALF, defaulting to 3.4 MHz against the real GC's ~27 MHz. At that rate the whole CDC response latency fits inside one bit time, so the suite passed green on a design that failed on console -- this is how both the wrong-header-format and the TX-pop-threshold bugs reached hardware with everything green. HALF is now EXI_HALF-configurable (default 8 for fast regression). At the real rate, EXI_HALF=1, every read comes back shifted right by ONE BIT: 04 02 02 00 -> 02 01 01 00, NWAYS 0x17 -> 0x0B. That is a bit-level sampling misalignment, not the byte-level latency chased earlier: at 54 MHz capture there are only 2 ticks per EXI bit and the 2-stage FFSynchronizer on EXI CLK costs 2 ticks, a whole bit. Recorded as an open bug in CLAUDE.md with the measurements. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
@@ -228,6 +228,35 @@ RX + 2 KB TX buffer at reset (`RMSR/TMSR=0x55`), so socket-3 frames are stored
|
||||
in the chip independently — no extra FPGA buffer needed. Register addresses are
|
||||
still datasheet-from-memory — **confirm at hardware bring-up**.
|
||||
|
||||
### ⚠️ The simulation clocks EXI 8× slower than hardware
|
||||
|
||||
`bba_top`'s testbench derives the EXI clock from `HALF` (capture ticks per SPI
|
||||
half-period): **EXI = 54 MHz / (2 × HALF)**. The default `HALF=8` gives
|
||||
**3.4 MHz** — eight times slower than the real GC's ~27 MHz. At that rate the
|
||||
entire CDC response latency fits inside one bit time, so the suite passes green
|
||||
on a design that fails outright on a console. **Both the wrong-header-format
|
||||
and the TX-pop-threshold bugs reached real hardware with a fully green test
|
||||
suite.**
|
||||
|
||||
`HALF` is now `EXI_HALF`-configurable. **Run `EXI_HALF=1 python -m
|
||||
exi_bba.bba_top` before trusting any timing-related change.**
|
||||
|
||||
Measured 2026-10-03:
|
||||
|
||||
| EXI rate | device ID | NWAYS |
|
||||
|---|---|---|
|
||||
| `EXI_HALF=8` → 3.4 MHz | `04 02 02 00` ✅ | `0x17` ✅ |
|
||||
| `EXI_HALF=2` → 13.5 MHz | ✅ | ✅ (TX drops 4 of 34 bytes) |
|
||||
| `EXI_HALF=1` → **27 MHz, the hardware rate** | `02 01 01 00` ❌ | `0x0B` ❌ |
|
||||
|
||||
⚠️ **OPEN BUG:** at the hardware rate every read comes back **shifted right by
|
||||
one bit** (`04 02 02 00` → `02 01 01 00`; `0x17` → `0x0B` = `0x17 >> 1`). This
|
||||
is a bit-level sampling misalignment, NOT the byte-level response latency that
|
||||
was chased earlier — at 54 MHz capture there are only 2 ticks per EXI bit, and
|
||||
the 2-stage `FFSynchronizer` on the EXI clock costs 2 ticks, i.e. a whole bit.
|
||||
On console the same build returns all zeros. Fix this before any further
|
||||
hardware runs.
|
||||
|
||||
### EXI on the J4 debug header (`EXI_J4=1`) — bench host without SP1
|
||||
|
||||
`EXI_J4=1` lets a bench host (the Pi) drive EXI through the unpopulated J4
|
||||
|
||||
Reference in New Issue
Block a user