fix(efuse): connect U13's exposed thermal pad to GND
The TPS25961's exposed pad is GND and the datasheet requires it be connected to the GND plane (Table 5-1; package note 3 adds a mechanical requirement). REVIEW.md claimed this was honoured because the footprint is the _ThermalVias variant -- but the variant alone connects nothing. hardware/TPS25961.kicad_sym defined pins 1-6 only, with no pin for the exposed pad, so KiCad had nothing to map onto footprint pad 7 and left it netless: an isolated copper island under the chip with its thermal vias going nowhere. Adds pin 7 (GND, power_in, hidden, stacked on pin 4) to the symbol library, the cached symbol in exi.kicad_sch, and the U13 instance. PCB updated and verified: U13 pad 7 carries GND on all four elements (both SMD rects and both thermal vias), R48 placed, EFUSE_OVLO routed, R49 gone. DRC reports 0 violations, 0 unconnected pads and 0 schematic parity issues -- the 0-unconnected result is what confirms pad 7 is tied into the GND network rather than merely labelled. The 4 DRC errors previously dismissed as zone-fill phantoms on this pad are gone, though zones were refilled in the same pass so that is not proof of cause either way. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
@@ -405,8 +405,26 @@ datasheet extraction, WebSearch/WebFetch for parts and reference designs.
|
||||
beyond that use an FPGA-read divider, not the eFuse enable.
|
||||
- **OVLO tied directly to GND** = internal fixed OV threshold. Note the OVLO
|
||||
pin's absolute maximum is only **6.5 V** — it must never see the 12 V rail.
|
||||
- **Thermal pad must connect to the GND plane** (datasheet requirement); the
|
||||
chosen footprint is the `_ThermalVias` variant for this reason.
|
||||
- ⚠️ **Thermal pad must connect to the GND plane** (datasheet requirement).
|
||||
The `_ThermalVias` footprint variant was chosen for this reason — **but
|
||||
that alone connected nothing, and the pad was floating until 2026-10-02.**
|
||||
`hardware/TPS25961.kicad_sym` defined **pins 1–6 only**, with no pin for the
|
||||
exposed pad, so KiCad had nothing to map onto footprint pad 7 and left it
|
||||
netless: an isolated copper island under the chip with its thermal vias
|
||||
going nowhere. Datasheet Table 5-1: *"GND | PAD | Thermal/Ground — the
|
||||
exposed pad is used primarily for heat dissipation and must be connected to
|
||||
GND plane on the PCB"*; package note 3 adds *"must be soldered to the PCB
|
||||
for thermal and mechanical performance"*.
|
||||
**Fixed 2026-10-02:** added **pin 7** (GND, `power_in`, hidden, stacked on
|
||||
pin 4 at the same coordinates) to `hardware/TPS25961.kicad_sym`, to the
|
||||
cached symbol in `exi.kicad_sch`, and as a `(pin "7")` entry on the U13
|
||||
instance. Netlist now shows **U13 pins 4 AND 7 on GND**; ERC 0 violations.
|
||||
**PCB ACTION REQUIRED: run *Update PCB from Schematic*** so pad 7 takes the
|
||||
GND net — until then the pad is still isolated on the board.
|
||||
Thermally this is not critical at the measured 56 mA load (steady-state
|
||||
loss ≈ 0.3 mW), but it matters in a fault: with no heat path the FET hits
|
||||
thermal shutdown sooner, changing the current-limit / 3-retry / latch-off
|
||||
behaviour. The mechanical requirement stands regardless.
|
||||
- Symbol: no TPS25961 exists in the KiCad libraries (the stock `TPS2596xx`
|
||||
is an 8-pin SO-8 with a different pinout — do not substitute it), so
|
||||
`hardware/TPS25961.kicad_sym` was created and registered in
|
||||
@@ -451,11 +469,22 @@ datasheet extraction, WebSearch/WebFetch for parts and reference designs.
|
||||
GUI refills all zones before DRC**, so the GUI (the authority) shows these
|
||||
clean. Confirmed 2026-08-02: a command-line DRC reported 18 such
|
||||
"errors" (14 GND-vias-over-3V3, 4 on U13's thermal pad) on a board the GUI
|
||||
reports clean. If you must DRC from the CLI, open the board in the GUI, run
|
||||
reports clean. **RESOLVED 2026-10-02:** after the thermal-pad fix (§6) and
|
||||
a PCB update, a CLI DRC reports **0 violations, 0 unconnected pads, 0
|
||||
schematic parity issues** — the U13 four are gone. Note the zones were also
|
||||
refilled in the same pass, so this does NOT prove the netless pad caused them
|
||||
rather than the stale fill; both changed at once. What it does confirm is
|
||||
that pad 7 now carries GND on all four elements AND counts as connected
|
||||
(0 unconnected pads), i.e. it is tied into the GND network rather than
|
||||
isolated. If you must DRC from the CLI, open the board in the GUI, run
|
||||
"Fill All Zones" (B), save, THEN run `kicad-cli` — or just trust the GUI.
|
||||
The board is DRC-CLEAN in KiCad.
|
||||
- **DRC (GUI, authoritative)**: 0 errors / 0 unconnected / 0 parity. Warnings
|
||||
are silkscreen cosmetics only (~150–170; JLC auto-clips).
|
||||
- **DRC: 0 errors / 0 unconnected / 0 parity** (CLI, 2026-10-02, after the
|
||||
eFuse rework — zones were current in the saved file so the CLI agreed with
|
||||
the GUI for once). Warnings are silkscreen cosmetics only: **293** as of
|
||||
2026-10-02 (199 `silk_overlap`, 89 `silk_over_copper`, 5
|
||||
`silk_edge_clearance`), up from ~150–170 before the rework. JLC auto-clips
|
||||
these; the rise is placement churn, not a new fault.
|
||||
- **JLC capability floor**: encoded as error-severity rules in
|
||||
`re-bba-rb.kicad_dru` (0.09 mm trace/space, 0.15 mm drill, 0.2 mm
|
||||
hole-to-copper etc.) — passing. Diff-pair impedance rules (USB 90 Ω,
|
||||
|
||||