docs: correct stale 'part fields blank' notes + flag kicad-cli zone-refill DRC trap
All eFuse/RExt/EE-CS parts (U13, R43-R47, C66, R44, D13) are picked with MPN+LCSC in the live BOM and placed+routed on the PCB - the TODO/REVIEW notes calling their fields 'intentionally blank' were written when the parts were first added and never updated. Corrected to reflect the committed state. Also documents the kicad-cli DRC gotcha that caused a false alarm: it does not refill zones, so it reports phantom GND-via-in-3V3-pour and thermal-pad clearance errors (actual 0.000mm) on a board the GUI reports clean. Added a warning at the top of TODO and in REVIEW section 7 so no future session mistakes it for a real defect. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
@@ -195,9 +195,10 @@ datasheet extraction, WebSearch/WebFetch for parts and reference designs.
|
||||
(F=25 MHz, ESR=50 Ω per the 16–31 MHz band, C0=3 pF max, CL=12 pF,
|
||||
gm=16.7 mA/V): **margin 7.53×**, against a DS requirement of ≥5 (the
|
||||
"6.99 dB" in Table 8 is 10·log₁₀5). **Ceiling is 100 Ω** — 120 Ω already
|
||||
fails the startup spec. Fitted value is a starting point; part fields are
|
||||
intentionally blank so it is re-selected/confirmed at bring-up by
|
||||
measuring drive level.
|
||||
fails the startup spec. Part is PICKED (UNI-ROYAL 0402WGF4999TCE, C25120 —
|
||||
the same 49.9 Ω already on R26–R29); the 49.9 Ω value is still a starting
|
||||
point to **confirm at bring-up** by measuring drive level (bench action
|
||||
only — the BOM line is not blank).
|
||||
- **Crystal symbol properties corrected 2026-07-31** (they were metadata-only
|
||||
errors, no copper impact, but they caused the regression above):
|
||||
Y1 CL 18 pF→**12 pF**, ESR 50 Ω→**80 Ω** (DS band 12–15 MHz),
|
||||
@@ -342,10 +343,19 @@ datasheet extraction, WebSearch/WebFetch for parts and reference designs.
|
||||
|
||||
## 7. PCB global / JLCPCB — REVIEWED, PASS
|
||||
|
||||
- **DRC**: 0 errors / 0 unconnected / 0 parity as of each review point
|
||||
(remaining parity items = the 11 debug/fix footprints awaiting placement +
|
||||
3 FTDI reroutes + R3 value sync — all listed by F8). Warnings are
|
||||
silkscreen cosmetics only (~150; JLC auto-clips).
|
||||
- ⚠️ **`kicad-cli pcb drc` DOES NOT REFILL ZONES — do not panic at its output.**
|
||||
It evaluates the zone-fill state *as saved in the file*, so any GND stitching
|
||||
via sitting in the 3V3 pour, or a thermal pad in the GND pour, is reported as
|
||||
a phantom `clearance`/`hole_clearance` error with "actual 0.0000 mm" — because
|
||||
the saved fill still has copper where the GUI would carve a void. **The KiCad
|
||||
GUI refills all zones before DRC**, so the GUI (the authority) shows these
|
||||
clean. Confirmed 2026-08-02: a command-line DRC reported 18 such
|
||||
"errors" (14 GND-vias-over-3V3, 4 on U13's thermal pad) on a board the GUI
|
||||
reports clean. If you must DRC from the CLI, open the board in the GUI, run
|
||||
"Fill All Zones" (B), save, THEN run `kicad-cli` — or just trust the GUI.
|
||||
The board is DRC-CLEAN in KiCad.
|
||||
- **DRC (GUI, authoritative)**: 0 errors / 0 unconnected / 0 parity. Warnings
|
||||
are silkscreen cosmetics only (~150–170; JLC auto-clips).
|
||||
- **JLC capability floor**: encoded as error-severity rules in
|
||||
`re-bba-rb.kicad_dru` (0.09 mm trace/space, 0.15 mm drill, 0.2 mm
|
||||
hole-to-copper etc.) — passing. Diff-pair impedance rules (USB 90 Ω,
|
||||
|
||||
Reference in New Issue