Commit Graph

3 Commits

Author SHA1 Message Date
Roflin 2458884160 Rework the EXI decoder to the real GC<->BBA protocol
Replaces the invented 2-byte header (addr split across both bytes, 2-bit
length field) with the protocol libogc and Swiss actually speak:

  command  (bit7=0, 6-bit reg)   [reg, 00, 00, data]  one 4-byte transfer
  register (bit7=1, 16-bit reg)  [0x80|w<<6, ah, al, 00] + data until CS

This was not an optimisation: the old decoder read Swiss's NWAYS read
(80 00 31 00) as 'write 0x31 to NCRA', and bit 0 of 0x31 is RESET, so every
register read would have reset the device.

Changes:
  * 16-bit address; no length field -- register reads and writes now stream
    until CS, like the SPRAM path already did
  * RHDR_LO starts the SPRAM fetch as soon as the address completes, using
    the trailing header byte as the prefetch window the protocol provides
  * command space serves EXI regs 0x02/0x03 (interrupt mask/status), the only
    two Swiss uses
  * EXI_GetID gets its own path: it offers just ONE header byte of warning, so
    the first ID byte is pushed the instant byte 0 identifies the query

Two timing subtleties, both found by simulation and commented in place:
  * MISO is driven LIVE from the tx FIFO head, so a byte pushed while the pad
    byte is on the wire appears in the pad slot.  A filler byte is parked
    there (MISO is don't-care through the header) so the first real response
    lands in data slot 0.
  * the prefetch must be one-shot; re-firing while waiting for the pad byte
    consumed the register stream early and shifted reads by a byte.

All testbenches updated to the real format and passing: bba_register_file
(7), bba_top (8 incl. the full W5100->SPRAM->GC loop and TX), exi_j4,
exi_capture, spi_mode3_slave, tx_frame_drain, spram_arbiter,
rx_frame_assembler, w5100_parallel_master.  gc_bba_test rebuilt against the
new protocol.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-03 11:58:52 +02:00
Roflin 80957f35db fix(tx): queue the frame length at TWD_HI so the drain runs concurrently
TXFrameDrain sat in IDLE until it had a length, and the length only reached
tx_ctrl when the NCRA ST bits were written -- after the GC had streamed the
whole frame.  So the entire frame had to fit in the 16-deep tx_bytes FIFO, and
BBARegisterFile silently drops bytes when w_rdy is low (SPI cannot
back-pressure).  On hardware this truncated frames at exactly 16 bytes: a
captured ARP had 16 correct bytes followed by the frame restarting over itself.

The length is now handed to the drain one cycle after the TWD_HI (0x35) write,
which the GC issues BEFORE streaming data.  The drain starts early and blocks
on tx_bytes_r_rdy, consuming bytes as they arrive, so tx_bytes becomes a
rate-matching buffer instead of whole-frame storage.  The ST write remains a
fallback trigger for software that skips TWD, guarded by tx_queued so one frame
is never queued twice.

Adds BBATop T8: streams a 34-byte frame (> the 16-deep FIFO) over EXI and
checks the W5100 model received it byte-for-byte.  Verified to FAIL without the
fix with exactly the hardware symptom -- 16/34 bytes, first bad byte at index
16.  The gap that let this ship: TXFrameDrain's own tests drive the FIFO
signals directly, and the BBATop test only covered the RX loop.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-30 18:49:04 +00:00
Dennis Brentjes 8d0ab1d948 Added full design created with Claude 2026-06-13 18:35:38 +02:00