Roflin 90a583dd46 Remove the device-ID one-shot: it made Swiss see no adapter at all
id_phase was set at reset and cleared permanently by the GC's first NCRA reset,
after which a command-space read of register 0 returned 0x00000000.  Swiss
calls EXI_GetID from bba_exists() AND again from bba_requires_init(), long
after init, and matches the result against EXI_MX98730EC_ID -- so with the
one-shot spent no case matched and Swiss reported NO ADAPTER, not a broken one.
Running gc_bba_test was enough to spend it, so the adapter would "disappear"
after any test session.

The justification in the comment was wrong.  It claimed the fast path would
otherwise hijack address 0 so the GC could never read NCRA back -- but NCRA is
REGISTER space (0x80/0xC0 header) while the fast path requires byte 0 == 0x00,
i.e. COMMAND space.  They were never ambiguous, and no driver reads command
register 0 for anything else (libogc2 reads 0x01/0x03/0x0B/0x0F, Swiss 0x03).
Real hardware answers EXI_GetID whenever asked; that is how EXI enumerates
devices.

id_arm is now tied high, and the id_phase output, the FFSynchronizer that
crossed it into the pin domain, and the BBATop wiring are all gone.  The port
stays only so the PHASE_METER build can disarm the fast path, which would
otherwise send ID bytes instead of its constant 0x80.

bba_top T1b reads the device ID AFTER an NCRA reset, which T1 (before any
reset) structurally cannot catch.  Mutation-tested: disarming the fast path
returns 00 00 00 00 for both, exactly what Swiss saw.

gc_bba_test: the ID tests no longer skip.  A wrong ID is a FAILURE again, with
no iface_alive() discrimination and no ordering requirement between suites --
the ID is readable at any point in a run.  g_ncra_reset_done and iface_alive()
are removed outright rather than left as a dead flag.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-10 14:33:12 +02:00
Roflin 4a455bbe88 Decode NCRB and the registers with non-zero hardware defaults
Compat TODO items 3 and 4.  Every register libogc2 writes now stores writes and
reads back, with the documented hardware reset defaults: NCRB (0x01), BP
(0x0A/0B), TLBP (0x0C/0D), RXINTT (0x14/15), RHBP (0x1A/1B), NWAYC (0x30,
default 0x84), GCA (0x32), MISC (0x3D, default 0x3C), MISC2 (0x50).  BP and
RHBP reset to OUR layout (page 1, page 15) so a driver reading them back
without writing sees something consistent with where the ring actually is.

Previously all of these read 0x00 and dropped writes, so a driver doing
read-modify-write or sanity-checking a default saw zero -- and libogc2 does
read NWAYC before writing it.

Deliberately still reading 0x00: LTPS, LRPS, TWP, TRP, TXFIFOCNT.  Those are
STATUS registers, not configuration, so storing what was written to them would
be a lie rather than a default.  Drivers read LRPS/LTPS only on error bits and
0x00 reads as "no error", which is truthful for a device that does not detect
them.

NCRB, BP and RHBP are also exported as BBARegisterFile.ncrb/.bp/.rhbp for the
RX-filtering work (item 1) and the ring-geometry check (item 2).  Nothing
consumes them yet -- the decode lands first so the behaviour that uses it is a
separate, testable change.

T15 checks the defaults, replays libogc2's twelve init writes in its order and
reads every one back, and asserts the NCRB export is 0x52 with PR=0, PM=0,
AB=1 -- i.e. that the real BBA delivers own-MAC + broadcast only, which is the
fact item 1 has to act on.  Mutation-tested: dropping NWAYC's 0x84 default
fails it, as does dropping NCRB writes.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-10 14:02:28 +02:00
Roflin 7116bc1ecc Implement the command registers libogc2 actually touches
Previously every command register except 0x02/0x03 read 0x00 and dropped
writes.  Real software will hit them, so they are now implemented, enumerated
from libogc2's gcif.c rather than guessed at random (Swiss's patch driver
touches only 0x02 and 0x03):

  0x01  read            revision ID -> priv->revid
  0x02  write           interrupt mask (IRMASKALL / IRMASKNONE)
  0x03  read / w1c      interrupt status
  0x04  write 2 bytes   priv->devid  = 0xD107
  0x05  write           priv->acstart = 0x4E
  0x08  read 4 bytes    challenge      | device-initiated path,
  0x09  write 4 bytes   response       | gated on status bit 0x10
  0x0B  read            challenge/response status
  0x0F  read (slow)     in __bba_reset(), result DISCARDED

0x01 returns 0x00 and is read-only.  That is a real-hardware value, not a
guess: the BBA never received a functional firmware revision that incremented
it.  libogc2's priv->revid = 0xf0 is its PRE-INIT PLACEHOLDER, overwritten by
whatever this read returns, so it must not be mistaken for the device value.
revid/devid/acstart feed only bba_calc_response(), whose path is
device-initiated, so they are functionally inert for us.

0x04 and up are plain read/write storage, which IS a guess: both drivers treat
them as write-only and never read them back, so read-what-you-wrote is the
least surprising behaviour and lets our tests confirm the write landed.
Ignoring them (the old behaviour) is strictly worse -- the write vanished.
Registers above 0x0F still read 0x00 so a stray high register cannot alias onto
a real one.

Noted for later: bba_cmd_in8_slow(0x0F) sits in __bba_reset() between two 10 ms
delays, holds CS for 200 us and discards the result.  A read whose value is
thrown away but whose timing is deliberate looks like a reset strobe; we treat
it as an ordinary register, and the NCRA reset follows immediately in that
sequence, so ignoring the side effect costs nothing today.

T14 covers the whole table and is mutation-tested: making 0x01 plain storage
fails it, and dropping the 0x04+ writes fails it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-10 11:24:23 +02:00
Roflin 0d100eb84f Implement the COMMAND-level interrupt: without it no driver sees a frame
The BBA has two interrupt levels and we implemented only one.  Both drivers'
handlers are identical in shape -- libogc2's bba_event_handler and Swiss's
exi_coroutine:

  status = bba_cmd_in8(0x03);            /* COMMAND level */
  bba_cmd_out8(0x02, BBA_CMD_IRMASKALL);
  if (status & 0x80) bba_interrupt();    /* ONLY then the MAC level */

and bba_interrupt() is what reads register-space IR/IMR and calls
bba_start_rx().  Bit 7 of command register 0x03 means "a MAC interrupt is
pending".  r_cmd_ir was write-1-clear with nothing ever setting it, so a
command read of 0x03 returned 0x00, every branch of both handlers fell through,
and NEITHER DRIVER WOULD EVER HAVE PROCESSED A RECEIVED FRAME.

Our own tooling could not have caught it: gc_bba_test and netboot poll RWP/IR
directly and never use the interrupt path, so the whole command-level mechanism
was untested and unused.  Green suite, dead interface.

cmd_ir[7] is now a live level equal to (IR & IMR) != 0, and INT_N is
(cmd_ir & cmd_imr) != 0.  A level rather than a latch because both drivers
clear the MAC IR inside bba_interrupt() and only then write-1-clear command
0x03: a latched bit would be cleared by that write even if a new frame had
arrived in between, while a level stays asserted as long as the condition does.
INT_N honouring the command-level mask is what stops the line re-asserting
while a handler runs (IRMASKALL on entry, IRMASKNONE on exit).  r_cmd_imr
resets to 0xF8 since the real power-on value is unknown and both drivers set it
explicitly first thing.

T13 and T13b cover it, both mutation-tested: reading the latched bits only
leaves 0x00 after an RI, and ignoring the command mask leaves INT_N asserted
through IRMASKALL.

Also records in CLAUDE.md which driver actually talks to us, since Swiss has
several back-ends and it is easy to read the wrong one: cube/patches/bba/ has
one file per chip (bba.c is ours; enc28j60.c, w5500.c, w6100.c, w6300.c are
other adapters), Swiss's menu networking goes through libogc2's gcif.c, and
cube/patches/bba/bba.c is the in-game patch driver.  Detection is by EXI device
ID, so returning 04 02 02 00 is what gets us handed to the BBA path at all.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-10 11:11:55 +02:00
Roflin b3685237b2 Support BOTH command-space forms: Swiss's 4-byte and libogc's 2-byte
Reading Swiss's own driver (cube/patches/bba/bba.c) shows the previous commit
fixed libogc and BROKE Swiss.  The two disagree, and both are real:

  Swiss   bba_cmd_out8: exi_imm_read_write(0x40<<24 | reg<<24 | val, 4)
          -> ONE 4-byte transfer [0x40|reg, 00, 00, val], and bba_cmd_in8
             returns the LOW byte, so a read response must be in BYTE 3.
  libogc2 bba_cmd_outsnosel: req = (reg<<8)|0x4000;
          EXI_ImmEx(&req, 2, WRITE); EXI_ImmEx(val, len, WRITE)
          -> THREE bytes, value in byte 2, and a read takes byte 2.
  stock libogc: identical to libogc2 (read out of libbba.a).

They share bytes 0 and 1 and differ only in how many bytes follow, so one
decoder serves both: take the LAST data byte before CS rise as the write value
(Swiss sends [00, val], libogc sends [val] -- last is val either way), and push
a read response TWICE so bytes 2 and 3 both carry it.  Swiss clocks 4 bytes and
pops both; libogc clocks 3 and leaves one, which the next transaction's header
pops drain -- a 2-byte header gives exactly one drain slot, so the leftover is
bounded at one and cannot accumulate.

Critically this means NO auto-increment of cmd_reg across the data phase: that
applied Swiss's padding 00 to the register and val to reg+1, which is precisely
how the libogc-only version broke Swiss.

T12 covers the Swiss form and asserts bytes 2 AND 3; T10 keeps the libogc form.
Both mutation-tested: re-adding the auto-increment fails T12 with 0x00 in both
slots, and pushing the response once fails T12's byte 3.  gc_bba_test gains
"cmd-space Swiss" alongside "cmd-space write", with bba_cmd_write4/read4.

Also corrects two things in CLAUDE.md now checkable against three drivers:
- NO driver writes TWD -- not Swiss, not libogc, not libogc2.  The "GC sets
  TWD before streaming" note was self-confirming: t_tx writes TWD because we
  wrote t_tx.  The counted TXDATA length is the primary path, not a fallback.
- Swiss's exi_dma_write rounds the length UP to 32 bytes (OSRoundUp32B), so
  TXDATA gets up to 31 trailing bytes past the frame and a counted length sends
  that much extra.  Real hardware must do the same since Swiss works on it;
  trailing padding past the IP total length is ignored.  A 1514-byte frame
  rounds to 1536 though, over the 1518 maximum.

Both drivers trigger TX with NCRA ST1, which the existing any-ST test accepts.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-10 11:01:33 +02:00
Roflin 71ec6a2b37 TX: count the TXDATA bytes, because libogc never writes TWD
Third contract checked against libogc rather than our notes.  __bba_link_tx is
four transactions -- read NWAYS, ONE register-space write of the whole frame to
0x0048, read NCRA, write NCRA = 0x04 -- with no TWD_LO/TWD_HI anywhere.  So the
device has to count the bytes it was handed.

The NCRA ST fallback queued tx_frame_len, which only TWD sets, so any driver
that skips TWD would have transmitted a stale or zero length.  BBARegisterFile
now keeps txdata_cnt, incremented per byte accepted at 0x0048 and cleared
whenever a frame is queued from either path, and the ST path queues that.

T11 drives TX in libogc's shape with no TWD write and checks both the queued
length and the drained bytes.  Mutation-tested: switching the ST path back to
tx_frame_len queues length 0, which is exactly the bug.  gc_bba_test gains the
hardware counterpart, "TX without TWD", which deliberately omits the TWD writes
that t_tx makes.

The TWD path stays and is still preferred when present: writing the length
before streaming is what lets TXFrameDrain consume concurrently and keeps
tx_bytes a rate-matching buffer rather than whole-frame storage.  Swiss writes
TWD, libogc does not, so both are supported.

Also recorded: libogc streams the payload with EXI_Dma (32-byte-aligned bulk
after PPCDCacheStoreAsync, then EXI_ImmEx for the remainder).  CLAUDE.md said
EXI DMA writes are avoided for the GC's 1-bit-shift bug; that is true of Swiss,
not libogc.  Nothing in the gateware changes -- a DMA write is just bytes
clocked in -- but the path will be exercised, and if that bug is real it
appears as corrupted TX frames that are not fixable here.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-10 10:49:11 +02:00
Roflin 0aa1fa884a Fix command-space writes, and replay libogc's real init sequence
Second protocol mismatch found the same way as the descriptor: by
disassembling libogc's own driver instead of trusting our notes.

COMMAND SPACE IS A 2-BYTE HEADER + DATA PHASE, not a single 4-byte transfer.
CLAUDE.md said [0x40|reg, 00, 00, data] and the decoder followed it, waiting
for a fourth byte and consuming the DATA byte as header byte 2 -- so every
command-space WRITE was silently dropped.  libogc's __bba_init writes command
register 2 (its interrupt mask) at both the start and the end of init, so none
of that took effect.  What it actually sends:

  EXI_Imm  (len=2, write) -> 42 00    the whole header, 0x4000 | (reg << 8)
  EXI_Sync
  EXI_ImmEx(len=1, write) -> 00       the data

Three bytes between CS fall and CS rise.  The device-ID read survived the wrong
decode only because SPIMode3Slave answers it on a fast path independent of this
FSM -- which is precisely why no test caught it: the only command-space traffic
under test bypassed the decoder being tested.

CHDR_2/CHDR_3 are replaced by CMD_WRITE, which takes the data byte straight
after header byte 1 and auto-increments the command register so a multi-byte
command write behaves like the register-space path.  cmd_wreg latches the
target because the write applies a cycle later, by which time cmd_reg has
moved on.  bba_register_file T10 writes command register 2 and reads it back,
and is mutation-tested: restoring the 4-byte decode fails it.

Also replaces the GUESSED init sequence in CLAUDE.md with the real transaction
list.  The old one was wrong in three ways that matter: libogc READS the MAC
out of PAR0-5 rather than writing one (so our reset value is what the console
uses), IMR is 0xDF not 0x86, and it writes RWP (0x0016/17) and RHBP (0x001A/1B)
which the register file does not accept.  The latter is harmless today -- RHBP
is 0x000F, matching our hardcoded 15-page ring -- but a driver configuring a
smaller ring would be ignored while the assembler kept writing outside it.

New gc_bba_test suite 7 "libogc init" replays the sequence on hardware:
cmd-space write (2-byte header, read back), MAC readable (one 6-byte PAR read,
Nintendo OUI), and init replay (all 30 writes in order, then NWAYS/HIPR/NCRA.SR
must still read correctly -- the old guessed header format turned a NWAYS read
into an NCRA reset, so a misdecoded write is a real risk).

bba.c gains bba_cmd_write/bba_cmd_read in libogc's shape.

Every module testbench and bba_top at EXI_HALF=1/2/8 pass.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-10 10:42:17 +02:00
Roflin ada9378628 Restore the TX-done clears to the TX handler; shorten the ACK timeout
TIMING MEASUREMENT, which is the useful part.  Raising the host timeout
0.1 -> 0.3 barely moved the retry count (110 -> 95) but tripled the cost of
each one: 16.9 s -> 40.1 s.  If those were LATE ACKs, three times the deadline
would have all but eliminated them.  They are LOST ACKs, so a SHORT timeout is
correct, not a long one -- the GC re-ACKs a duplicate block, so retrying early
costs nothing.  Host default is now 0.05.

REGRESSION, mine, from 92f7d71.  Inserting the RBFI handler split the TX-done
block, leaving these two lines attached to rx_overflow -- an RX event:

    m.d.sync += r_ncra[1:3].eq(0)  # clear ST bits
    m.d.sync += tx_queued.eq(0)    # ready for the next frame

So after the first transmit tx_queued stayed set forever.  The NCRA ST
fallback trigger is guarded on ~tx_queued, so software driving TX via ST
rather than TWD would transmit exactly ONCE and then silently stop, and the ST
bits were left asserted in NCRA.  Our own path arms via TWD, which is why it
kept working and why this was not noticed.

T9 covers it and is mutation-tested: with the clears misplaced, NCRA reads
0x0A with ST stuck set.

This does NOT explain the 1/3 ACK loss -- the TWD path was unaffected -- so
that remains open.  txto from the next run is the discriminator: near zero
means the frames reach the W5100 and are lost after that, which points at the
chip's TX handling rather than the EXI side.

--seeds 8: clk 27.5-29.4 MHz, EXI 54.7-62.3 MHz, 8/8 PASS.  Best seed 5
(clk 29.41, EXI 60.22), flashed.  The .dol is unchanged; only send-dol.py's
default timeout moved, and that is read from the repo.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-09 19:54:23 +02:00
Roflin d67f111019 Don't advance the write address across TXDATA; deepen tx_bytes to 2048
Two coupled fixes, both exposed by batching TXDATA writes in the test app.

1. eff_addr advanced on EVERY data byte of a register-space write.  But
   TXDATA (0x48) is a FIFO PORT, not a register: a whole frame is written to
   that one address.  So an 8-byte write put byte 0 in TXDATA and bytes 1..7
   into 0x49+, which the switch silently ignores.  The frame was an eighth of
   its declared length, TXFrameDrain blocked waiting for the rest, and TI
   never set (hardware: txto=16, "no ACK after 20 tries").

   SWISS WOULD HAVE HIT THIS.  It writes an entire frame with bba_outs to
   BBA_WRTXFIFOD -- one transaction, one address -- so its TX would have
   delivered ONE BYTE per frame.  The path was never exercised because the
   test app wrote TXDATA one byte per EXI transaction, giving every byte a
   fresh header at 0x48.  Every other register must still advance, so that
   bba_outs can write PAR0-5 or MAR0-7 as a block; the exception is TXDATA
   only.

2. tx_bytes was 16 deep.  SPI cannot back-pressure -- there is no way to tell
   the GC to wait -- so BBARegisterFile silently drops bytes when w_rdy is
   low, which makes the depth the only thing between a drain stall and a
   corrupted frame, not a buffering preference.  16 bytes is ~4.7 us at the
   EXI byte rate, and TXFrameDrain shares the W5100 bus arbiter with RX and
   the socket-3 UDP test, so any longer stall truncated a frame mid-flight.
   With (1) fixed, Swiss streams up to 1514 bytes in a single transaction, so
   16 could never have held.

   Now 2048: a whole maximum-size frame plus margin, so a frame cannot be
   truncated even if the drain makes no progress for the entire transaction.
   Costs 3 of 27 free BRAMs (ICESTORM_RAM 3/30 -> 6/30, LC 68% -> 70%).

   Dennis spotted that the 8-byte workaround could not survive whole-frame
   writes, which is what prompted fixing the depth rather than shipping it.

bba_tx_bytes() consequently streams 64-byte chunks (bba_write()'s buffer
limit), so a 60-byte ACK is ONE transaction instead of sixty.

T8 covers both and is mutation-tested: restoring the increment gives
"1/8 bytes MISMATCH -- got [17], want [17, 34, 51, ...]".  It now writes 64
bytes so it exercises the deepened FIFO too.

--seeds 8: clk 27.6-29.4 MHz, EXI 51.2-64.7 MHz, 8/8 PASS.  Best seed 1
(clk 29.35, EXI 60.80), flashed.

STILL NO FLOW CONTROL on the TX path: a frame larger than 2048 would drop
silently rather than error.  Fine for ethernet's 1518 ceiling; revisit if the
multiworld socket work ever wants larger payloads.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-09 19:36:21 +02:00
Roflin e9b1a75bfe Discard SPRAM responses with no request outstanding
SPRAMArbiter gives ETH writes ABSOLUTE priority -- eth_wr_ready is asserted
combinationally whenever eth_wr_valid is high, so the write port is never
stalled.  Two consequences worth recording:

  - The T5 stall model added to rx_frame_assembler does NOT reflect hardware.
    Its value was eliminating a hypothesis, not modelling reality.
  - EXI READS are what get preempted, so a read response can be delayed --
    including past the end of the transaction that asked for it.

The register file did not guard against that.  The response handler pushed
whatever arrived, and HEADER0 reset `outstanding` and `sp_req` but not
`sp_pending`.  So a late response was pushed into tx_fifo anyway, a held byte
leaked across the transaction boundary, and `outstanding - 1` from zero
underflowed a 4-bit counter to 15 -- which then broke the prefetch bound for
the rest of that transaction.

Now guarded on (outstanding != 0), and sp_pending is cleared in HEADER0.

WHAT THIS DOES NOT CLAIM.  I cannot demonstrate that this causes the +1
descriptor offset seen on hardware (17 of 22 frames, varying frame to frame).
A test written in bba_register_file passes with AND without the guard --
checked both ways -- because that testbench models TX as a capture list per
transaction, with no persistent tx FIFO and no header drain pops, which is
precisely the mechanism by which a leaked byte would shift the next read.  A
test that cannot fail is worse than no test, so it is deleted rather than
banked, and the gap is documented where it was.

THE MISSING TEST, recorded in bba_register_file.py: a bba_top-level test that
performs an EXI DMA read from the SPRAM ring WHILE the ethernet side writes
frames into it.  Only under that overlap can a response be delayed past its
transaction.  No simulation does this today, which is why the offset is still
formally unexplained -- the fix here is a real latent bug, not a proven cause.

--seeds 8: clk 28.1-30.3 MHz, EXI 54.9-62.3 MHz, 8/8 PASS.  Best seed 7
(clk 30.26, EXI 61.09), flashed.  Gateware only -- .dol unchanged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-09 19:00:35 +02:00
Roflin 92f7d716d9 Add RBFI ring-overflow protection: drop frames instead of overwriting
RXFrameAssembler ignored RRP entirely, so it lapped the reader: a traffic
burst overwrote pages the GC had not read, and the "descriptor" the driver
then parsed was frame data from whatever had replaced it.  That is where the
hardware's 00 00 00 01 came from -- not a dropped write.

This is a product bug, not just a netboot one.  Until now ANY burst could
corrupt a frame Swiss was midway through reading, with nothing to indicate it
had happened.

The assembler now takes the GC's read pointer and computes free space as
(rrp - rwp - 1) mod 15.  On a frame start with fewer than 6 free pages -- the
worst case for 1518 bytes plus a 4-byte descriptor -- it enters DROP_FRAME,
discards to EOF, and pulses rx_overflow, which sets IR[7] (RBFI).  That is the
bit the GC's IMR = 0x86 already enables, so a driver that loses a frame is
told so instead of reading corruption.

Deliberate details:
  - rx_ready stays HIGH while dropping.  Stalling the ethernet master instead
    would back-pressure into the W5100's own buffer and turn a dropped frame
    into a wedged receiver.
  - Six pages are reserved up front because a frame's length is not known
    until EOF.  Starting with less risks running into unread data partway
    through, which is worse than refusing cleanly.
  - have_room is REGISTERED, not combinational.  Feeding a mod-15 subtract and
    comparator into the FSM branch cost real depth in `sync`, the domain with
    the least margin: clk fell 27.8-32.2 -> 27.0-28.0 MHz.  Registering it
    restored 28.4-31.4.  One cycle of staleness is harmless -- rwp moves only
    at end-of-frame and rrp only when the GC writes it.

T4 proves the property that matters, and the negative control REPRODUCES THE
HARDWARE FAULT IN SIMULATION: with the check removed the unread page reads
back as [245, 248, 251, 254, ...] -- frame data where a descriptor belongs.
First time one of today's RX faults has been reproducible on this side rather
than inferred from the console.  T4 also checks the receiver un-latches once
RRP advances, so a full ring cannot kill RX permanently.

Fixed a test artifact in the same pass: rx_overflow fires on the very tick
that consumes the EOF byte, inside send_frame, so polling for a 1-cycle pulse
afterwards missed it and a correctly-dropped frame looked like a stall.  Both
pulses are now latched in the tick helper.

netboot also clears IR (including RBFI) at init so a stale bit is not
inherited from an earlier run.

--seeds 8: clk 28.4-31.4 MHz, EXI 55.2-62.7 MHz, 8/8 PASS.  Best seed 4
(clk 31.39, EXI 61.85), flashed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-09 12:36:07 +02:00
Roflin 83a62d60a0 Reset the register file's ring pointers on an NCRA reset
An NCRA reset returns RXFrameAssembler's write pointer to page 1, but the
register file's COPY of RWP was never reset -- it kept whatever the last frame
left.  So after any reset the GC reads a stale RWP pointing at a page the
assembler is not using, and its first RX after a reset reads the wrong page.

CLAUDE.md has stated the intent all along ("NCRA = 0x01 ... resets W5500 +
SPRAM ptrs"); the register file simply never did it.

This is NOT only a netboot problem.  Any driver that resets and then trusts
RWP hits it, Swiss included.  It stayed invisible because the suite's RX test
only checks that RWP CHANGES, never that it points at the right page, and
t_dma used to read a hardcoded 0x100 so it never consulted RWP either.  It
surfaced through netboot, whose RRP = RWP sync landed on a stale page and
found garbage where a descriptor should be.

T1c covers it, and BOTH halves have teeth.  My first version did not: RWP read
[1] with or without the fix because nothing in the testbench had moved it.  It
now drives the assembler's RWP update path to page 9 and writes RRP to 7
first, so the negative control fails on both:

    T1c RWP after NCRA reset: expected [1], got [9]
    T1c RRP after NCRA reset: expected [1], got [7]

A test that passes whether or not the fix is present is worse than no test.

Gateware only -- the test app needs no change and the existing .dol is
compatible: after its reset it reads RWP, now gets 1, and writes RRP = 1.

--seeds 8: clk 28.5-32.2 MHz, EXI 51.3-63.4 MHz, 8/8 PASS.  Best seed 2
(clk 32.19, EXI 63.23), flashed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-09 11:44:03 +02:00
Roflin 3db4ab0851 Reset both SPRAM ring pointers to page 1, not 0
The DMA descriptor test reported "RRP page 0 outside ring pages 1-15" on a
board whose RX path was working (t_rx passed: RWP advanced and RI fired), so
the pointer itself was wrong.

RXFrameAssembler's write pointer resets to _RX_PAGE_FIRST = page 1 -- the ring
is pages 1-15 and page 0 holds the register region -- but the register file's
r_rwp_lo and r_rrp_lo were plain Signal(8) and reset to 0.  Two consequences:
the register file and the assembler disagreed about where the ring starts, and
a driver reading its first frame from RRP=0 gets the REGISTER page instead of
the frame, which is at page 1.

It hid because RRP == RWP == 0 looks self-consistently empty, so nothing
complained until something actually read the pointer.  RRP is driver-owned
(the GC writes it after consuming frames) but its RESET value is ours, and
RRP == RWP == 1 is the correct initial state: empty, pointing at the ring
start.

T1b locks down both reset values AND imports the assembler's constant to
assert it matches, because two copies of a page number in two modules is
exactly how the off-by-one got in.

--seeds 8: clk 28.x-32.2 MHz, EXI 56-60 MHz, 8/8 PASS.  Best seed 8, flashed.

NOT fixed here, and worth separate attention: nothing in the gateware consumes
RRP, so RXFrameAssembler can overwrite pages the GC has not read yet -- there
is no ring-overflow protection (the real BBA has RBFI for this).

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-09 11:06:22 +02:00
Roflin 7587636b48 Answer the device-ID query from the bit engine, not the register file
bba_devid fails on a console with 00 04 02 02 -- the ID correct but one byte
late -- and it fails in its REAL shape, with the 16 us gap and exactly four
bytes clocked, so this is not the t_raw_id probe artefact.  The register suite
passes, so register-space reads are fine; only command space is affected.

Cause is latency, not phase.  A command-space header is two bytes, so the
reply must be in the tx FIFO by the LAST RISING EDGE of the header transfer:
one byte time, 296 ns at 27 MHz.  The round trip is rx AsyncFIFO (~125 ns) +
a sync cycle + tx AsyncFIFO (~110 ns) = 280-320 ns, marginal by construction.
HEADER0 already pushed in the same cycle it consumed byte 0, so the FSM side
was already as early as it can be.

The inter-transfer gap cannot rescue it: the load happens on that last rising
edge and the clock is PAUSED afterwards, so no edge exists during the gap for
anything to update.  That is why bba_devid's 16 us gap makes no difference.

Pre-pushing the ID at CS-fall does not work either -- the engine's
unconditional per-byte pops would eat it, and the header length is not known
until byte 0 has been decoded, which is the latency in question.

So take the round trip out of the path.  The device ID is a hardwired constant
and belongs to the physical interface rather than to the register file, and
byte 0 == 0x00 identifies the query exactly (bit 7 clear = command space, bit
6 clear = read, reg 0).  SPIMode3Slave now recognises it and answers
04 02 02 00 from the EXI clock domain, with no CDC at all.  The only thing it
needs from sync is id_phase, a single bit that changes once, crossed with an
FFSynchronizer.

The register file's ID path is REMOVED rather than kept as a fallback: left
in, it would push bytes that a 2-byte header has too few pops to drain, which
is exactly how an earlier version made the NEXT enumeration come back a slot
late.

Tests follow the responsibility:
  - spi_mode3_slave T7: the query returns 04 02 02 00 with the tx FIFO
    deliberately feeding 0x00, so only the fast path can be answering.
  - spi_mode3_slave T8: and it is GATED -- with id_arm low, 0x5A comes
    through from the FIFO.  Without this the fast path would hijack address 0
    forever and the GC could never read NCRA back after its own reset.
  - bba_register_file T1: retargeted to assert the FSM pushes NOTHING for an
    ID query, which is the property that stops stale bytes corrupting the
    following transaction.

Note what these tests do NOT establish: bba_top already passed the device ID
at EXI_HALF=1 before this change, because simulation cannot reproduce a
296 ns window miss -- the sync domain's latency relative to the EXI clock in
sim does not match silicon closely enough.  T7/T8 prove the fast path works;
the evidence that it is NECESSARY is the hardware result plus the paused-clock
argument above.

--seeds 8: clk 28.4-31.0 MHz, EXI 56.7-64.4 MHz, 8/8 PASS.  Best seed 2
(clk 30.98, EXI 59.47), flashed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-09 10:51:37 +02:00
Roflin 91c3bf0ece Clock the EXI bit engine from the EXI pin: timing closes on all 8 seeds
Replaces the PLL-fed 54 MHz `capture` domain, which oversampled the GC's
27 MHz EXI clock 2x and so put BIT-level timing across a CDC boundary: the
engine's view of the clock lagged the pin by 2 FFSynchronizer stages plus a
register (~55 ns) against a 37 ns bit time, so MISO came out ~2 bits late and
the GC read 0x17 as 05 C0.  No amount of oversampling fixes that -- 54 MHz
gives only 2 ticks per bit and the part cannot close the 81 MHz that 3x needs.

The engine is now clocked by the pin itself (pin 44 = global buffer input net
6, no board change), making MISO clock-to-Q.  ExiCapture creates four domains:
exiclk (posedge, samples MOSI), exiclk_n (negedge, drives MISO), both
async-reset by CS, plus reset-less exififo_w/exififo_r for the byte FIFO sides
-- reset-less because resetting one side of an AsyncFIFO desynchronises its
gray pointers, and posedge because AsyncFIFO has a posedge-only reset CDC
internally and cannot host a negedge side.

Also removes the SPRAM response FIFO.  The DMA read was one byte late because
the round trip did not fit the protocol's turnaround byte; the arbiter already
exposed valid/ready, so the FIFO bought a cycle of latency and nothing else.
The response is handled outside the FSM (the reply lands in RHDR_PAD, not
SPRAM_STREAM) with a one-entry hold for when tx_fifo is momentarily full.

The PLL was left instantiated but unused after the rewrite; removing it frees
the hard macro and pin 35 (which stays unconnected only because the board is
already built that way).  This is what lifted the pass rate:

  domain            target    before        after
  clk (sync)        24 MHz    28.1-30.2     26.4-32.2   8/8
  capture_clk       54 MHz    2 of 8 PASS   (gone)
  EXI pin domain    27 MHz    --            45.6-64.4   8/8

Best seed 3: clk 32.18 MHz, EXI 55.86 MHz.  The binding constraint has FLIPPED
-- `clk` (1.10-1.34x) is now tighter than the EXI domain (1.69-2.39x) -- so
synth.py ranks seeds by worst RELATIVE margin, not by the EXI number.

synth.py could not have scored this design at all: it required the vanished
capture_clk, and its regex '(\w+)' cannot match nextpnr's exi_clk_$glb_clk
(no $ in \w).  add_clock_constraint was also landing on the wrong net -- under
EXI_J4 the clock is the AND of two pads, not either pad -- so nextpnr silently
fell back to a 12 MHz default and under-optimised the whole EXI domain.

Testbenches:
- spi_mode3_slave had lost its testbench entirely in the rewrite.  Restored
  with a strict Mode 3 master (changes MOSI on the falling edge, samples MISO
  in the clock-low phase) and MUTATION-TESTED: flipping either clock edge in
  the RTL makes it fail.  Both of those bugs previously reached silicon
  against a lax master that parked MOSI well before the edge.
- exi_j4 T2/T3 returned [0,4,2,2].  Real bug: the engine latches the FIFO head
  at each byte boundary, so a 2-byte command header leaves only ONE drain
  slot.  DEVID streamed zeros until CS and left two stale bytes -- one too
  many -- so the NEXT enumeration came back a slot late.  DEVID now pushes
  exactly four bytes and stops.  Register-space reads may still over-push:
  their 4-byte header gives three drain slots.
- Dead ports removed from SPIMode3Slave (hdr_bytes, frame_start, cs_active,
  byte_idx) and the mode2 parameter is gone -- there is one correct edge
  convention and it is now enforced by tests.

All 14 module suites pass, plus bba_top at EXI_HALF=1/2/8.

CLAUDE.md: rewrote the clocking, CDC inventory and module tables; marked the
2026-09-30 capture_clk measurements historical; and corrected the line in
"Critical Protocol Notes" that still stated the INVERTED edge convention
("MOSI sampled on falling, MISO driven on rising" is Mode 2) -- the original
implementation followed that doc error.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-03 18:36:51 +02:00
Roflin 02239466fb Merge the exi and sync domains into one
bba_top wired ClockSignal("sync") to ClockSignal("exi"), so the two "domains"
were always the same physical clock net.  Everything between them -- six
AsyncFIFOs and three PulseSynchronizers -- was pure latency and logic for a
crossing that did not exist.

  * the six AsyncFIFOs become plain SyncFIFOs
  * the three PulseSynchronizers become wires
  * BBARegisterFile and ExiCapture move from m.d.exi to m.d.sync
  * the exi ClockDomain is gone; HFOSC drives sync directly

The SPRAM request write port is also combinational now.  A registered w_en
costs a 24 MHz cycle, and the protocol's turnaround byte (~296 ns at 27 MHz)
has no cycles to spare.

Passing: bba_register_file, spram_arbiter, rx_frame_assembler, tx_frame_drain,
w5100_parallel_master, uart_shell, status_panel.  bba_top at EXI_HALF=1
(27 MHz, the hardware rate) passes device ID, PAR read/write, NWAYS, RWP and
the 34-byte TX frame.

STILL OPEN: the SPRAM/DMA read is one byte late.  Removing the CDC was not
enough -- the remaining round trip is the rx crossing (exiclk->sync, a REAL
CDC, ~125 ns) plus FSM decode plus the spram_req FIFO, arbiter, SPRAM access
and spram_rsp FIFO, which still exceeds the turnaround byte.  Next step: now
that it is all one domain, drop the two SPRAM FIFOs entirely and give the
register file a direct request/grant port on the arbiter -- that should take
the round trip to ~2-3 cycles and fit.

exi_capture and exi_j4 testbenches still assert removed behaviour (the CS-fall
flush and the old MISO slot timing) and need rewriting for the clocked engine.
Still WIP -- do not flash.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-03 17:02:58 +02:00
Roflin 399fbf02a4 fix(exi_capture): TX pop threshold must follow the header length
tx_fifo.r_en popped from txld_cnt >= 2, hard-coded for the old invented
2-byte header where the data phase began at slot 2.  The real protocol's
register space uses a 4-byte header, so data starts at slot 4 -- two bytes
were being consumed before the GC clocked any data, and every register read
came back wrong.  On hardware: HIPR and NWAYS both read 0x00, and the device
ID returned 01 80 c0 c0 (stale bytes, including our own header command bytes
0x80/0xC0 echoing back out of the FIFO).

The threshold is now derived from byte 0 bit 7, which is exactly what selects
the header form:  register space -> 4 slots, command space -> 2 slots.

Also removes the pad-slot filler byte the register file was pushing.  That was
compensating for this bug rather than fixing it -- it made the simulation pass
while hardware still failed, which is how it slipped through.  With the pop
threshold correct the filler is wrong, and both the unit and integration
testbenches agree without it.

All suites pass: bba_register_file, bba_top, exi_capture, exi_j4,
spi_mode3_slave, tx_frame_drain, spram_arbiter, rx_frame_assembler,
w5100_parallel_master.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-03 12:27:31 +02:00
Roflin 2458884160 Rework the EXI decoder to the real GC<->BBA protocol
Replaces the invented 2-byte header (addr split across both bytes, 2-bit
length field) with the protocol libogc and Swiss actually speak:

  command  (bit7=0, 6-bit reg)   [reg, 00, 00, data]  one 4-byte transfer
  register (bit7=1, 16-bit reg)  [0x80|w<<6, ah, al, 00] + data until CS

This was not an optimisation: the old decoder read Swiss's NWAYS read
(80 00 31 00) as 'write 0x31 to NCRA', and bit 0 of 0x31 is RESET, so every
register read would have reset the device.

Changes:
  * 16-bit address; no length field -- register reads and writes now stream
    until CS, like the SPRAM path already did
  * RHDR_LO starts the SPRAM fetch as soon as the address completes, using
    the trailing header byte as the prefetch window the protocol provides
  * command space serves EXI regs 0x02/0x03 (interrupt mask/status), the only
    two Swiss uses
  * EXI_GetID gets its own path: it offers just ONE header byte of warning, so
    the first ID byte is pushed the instant byte 0 identifies the query

Two timing subtleties, both found by simulation and commented in place:
  * MISO is driven LIVE from the tx FIFO head, so a byte pushed while the pad
    byte is on the wire appears in the pad slot.  A filler byte is parked
    there (MISO is don't-care through the header) so the first real response
    lands in data slot 0.
  * the prefetch must be one-shot; re-firing while waiting for the pad byte
    consumed the register stream early and shifted reads by a byte.

All testbenches updated to the real format and passing: bba_register_file
(7), bba_top (8 incl. the full W5100->SPRAM->GC loop and TX), exi_j4,
exi_capture, spi_mode3_slave, tx_frame_drain, spram_arbiter,
rx_frame_assembler, w5100_parallel_master.  gc_bba_test rebuilt against the
new protocol.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-03 11:58:52 +02:00
Roflin 80957f35db fix(tx): queue the frame length at TWD_HI so the drain runs concurrently
TXFrameDrain sat in IDLE until it had a length, and the length only reached
tx_ctrl when the NCRA ST bits were written -- after the GC had streamed the
whole frame.  So the entire frame had to fit in the 16-deep tx_bytes FIFO, and
BBARegisterFile silently drops bytes when w_rdy is low (SPI cannot
back-pressure).  On hardware this truncated frames at exactly 16 bytes: a
captured ARP had 16 correct bytes followed by the frame restarting over itself.

The length is now handed to the drain one cycle after the TWD_HI (0x35) write,
which the GC issues BEFORE streaming data.  The drain starts early and blocks
on tx_bytes_r_rdy, consuming bytes as they arrive, so tx_bytes becomes a
rate-matching buffer instead of whole-frame storage.  The ST write remains a
fallback trigger for software that skips TWD, guarded by tx_queued so one frame
is never queued twice.

Adds BBATop T8: streams a 34-byte frame (> the 16-deep FIFO) over EXI and
checks the W5100 model received it byte-for-byte.  Verified to FAIL without the
fix with exactly the hardware symptom -- 16/34 bytes, first bad byte at index
16.  The gap that let this ship: TXFrameDrain's own tests drive the FIFO
signals directly, and the BBATop test only covered the RX loop.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-30 18:49:04 +00:00
Dennis Brentjes 8d0ab1d948 Added full design created with Claude 2026-06-13 18:35:38 +02:00