Replaces 54 MHz oversampling with a slave clocked by EXI CLK itself:
exiclk posedge sample MOSI (Mode 3 samples on edge 2)
exiclk_n negedge drive MISO (must settle between the master's samples)
CS_N async reset for both
EXI CLK (pin 44) is at die (6,0) = global buffer net 6 on the 5k-sg48, so it
can drive a real clock network with no board change.
This removes the capture domain entirely. Bit-level timing no longer
crosses a clock boundary -- MISO is clock-to-Q instead of 3 ticks of a foreign
clock -- and the only crossings left are the byte FIFOs, which have a whole
byte-time (~296 ns) of slack rather than a fraction of a bit.
AsyncFIFO needs a posedge clock for its internal reset CDC, so the FIFO sides
use reset-less POSEDGE domains on the same pin; the engine pops on the posedge
and hands the byte to the negedge output stage through a register. The FIFOs
must not see CS: resetting one side of an AsyncFIFO desynchronises its gray
pointers.
Two bugs found and fixed along the way:
* one pop per byte boundary is all that is needed -- pops during the header
drain whatever the previous transaction left (replacing the CS-fall flush)
and the turnaround-byte push lands in data slot 0. No slot-threshold or
header-length logic at all.
* rx_byte/rx_valid had to become COMBINATIONAL. Registered, they need one
more clock edge, and after a transaction's final bit the clock stops and
CS rises -- so the last byte of every transaction was lost (a 4-byte write
landed as DE AD BE 00, a 34-byte TX as 15 bytes).
At the HARDWARE rate (EXI_HALF=1, 27 MHz) the device ID, NWAYS, PAR
read/write and the W5100->SPRAM RX path now all pass -- none of which has ever
worked at 27 MHz before. Testbenches now drive the SPI clock with real
delays, since there is no capture domain to count ticks against.
STILL BROKEN: the SPRAM/DMA stream is offset by one byte (its round trip
exceeds the single turnaround byte), and TX lands 15 of 34 bytes. Do not
flash this yet.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
The docs call this 'Mode 3 (CPOL=1, CPHA=1)' and then describe sampling MOSI
on the FALLING edge. Idle-high plus sample-on-falling is Mode 2. Real Mode 3
samples on the second edge of each cycle, which with an idle-high clock is the
RISING one, and that is what the GameCube does.
Sampling on the same edge the GC drives MOSI latched the PREVIOUS bit, so
every byte arrived one bit late in both directions, at every clock speed:
the 0x80 register-space header byte was read as 0x00, which decodes as a
command-space device-ID query -- so NWAYS reads returned the device ID and the
speed sweep failed at every index. Hardware raw dump, first transaction after
an FPGA reset:
00 00 02 01 01 00 00 00 02 01 01 00 = 04 02 02 00 >> 1
The Pi probe never caught it because that script was written to match this
device, and every simulation testbench drives MOSI many capture ticks before
toggling the clock, so MOSI is stable at BOTH edges and the convention cannot
be distinguished. The bba_top master now models a true Mode 3 master (drive
on falling, sample on rising) so the suite can tell the difference.
SPIMode3Slave(mode2=True) restores the old behaviour for the Pi/J4 probe.
Known remaining issue: at EXI_HALF=1 (27 MHz, 2x oversampling) reads are still
shifted, because the 2-stage input FFSynchronizer costs 2 capture ticks which
at 27 MHz is a whole bit. That is a separate fault and only bites at 2x.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>