First silicon proof of the EXI capture path. A Pi bit-banging EXI into J4
reads the device ID 04 02 02 00 21/21, NWAYS 0x17, HIPR 0x01, writes and reads
back PAR0-3, writes IMR, and sees NCRA's reset bit self-clear.
Fixes two host-side bugs found getting there:
- exi_devid_rpi.py sampled MISO just after the rising edge, racing the slave's
own update and landing one bit early (04 came back as 08). Sample in the
CLK-low phase, as the simulation does.
- pi-exi-wirecheck.py's bridge scan drove HIGH against pull-downs, but the
FPGA's SB_IO pull-up out-pulls the Pi's internal pull-down, so every pin
reported as bridged. The aggressor now drives LOW against pull-ups.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Verifies the harness before attempting a real EXI transfer. Keyed on the
EXI_J4 build's SB_IO pull-ups: an FPGA input with PULLUP=1 reads HIGH when
connected, follows the Pi's pull when open, and reads a hard 0 only when
shorted -- so all three cases are distinguishable from the Pi alone.
Includes a T0 control on known-unwired pins; without it a broken pull
mechanism would turn every 'connected' verdict into a false pass.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>