tx_fifo.r_en popped from txld_cnt >= 2, hard-coded for the old invented
2-byte header where the data phase began at slot 2. The real protocol's
register space uses a 4-byte header, so data starts at slot 4 -- two bytes
were being consumed before the GC clocked any data, and every register read
came back wrong. On hardware: HIPR and NWAYS both read 0x00, and the device
ID returned 01 80 c0 c0 (stale bytes, including our own header command bytes
0x80/0xC0 echoing back out of the FIFO).
The threshold is now derived from byte 0 bit 7, which is exactly what selects
the header form: register space -> 4 slots, command space -> 2 slots.
Also removes the pad-slot filler byte the register file was pushing. That was
compensating for this bug rather than fixing it -- it made the simulation pass
while hardware still failed, which is how it slipped through. With the pop
threshold correct the filler is wrong, and both the unit and integration
testbenches agree without it.
All suites pass: bba_register_file, bba_top, exi_capture, exi_j4,
spi_mode3_slave, tx_frame_drain, spram_arbiter, rx_frame_assembler,
w5100_parallel_master.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
An interactive UART command shell drives a UDP send/receive test on the
W5100's socket 3, running ALONGSIDE the live BBA (socket-0 MACRAW) with
EXI keeping bus priority. MACRAW+UDP coexistence is W5100S-datasheet
confirmed (S4.6 + "4 independent SOCKETs"). Now the default flash build
(--console selects the old event-log console).
New / changed gateware:
- uart_shell.py (new): rebbarb> shell over FT2232H channel B. Commands:
help; udp unicast <ip> [msg]; udp broadcast [msg]. After each send it
waits (bounded, else "timeout") for a reply and prints "rx <payload>".
Line buffer + message ROM live in block RAM with a sequential parser
(LC-efficient); 1-deep RX holding reg keeps pastes intact. 8 sim tests.
- w5100_parallel_master.py: configurable UDP socket (default 3) with UDP
send AND receive (IP-stack init, runtime dest IP, WIZnet UDP RX header
+ payload). Gated by enable_udp_test so the MACRAW path is unchanged
when off. Tests U1-U4 + MACRAW T1-T5.
- exi_capture.py: CAPTURE-DOMAIN CRITICAL-PATH FIX. The TX byte-FIFO
read-enable was gated by its own gray-coded ready
(r_en = ... | (flushing & r_rdy)), forming a consume_ptr -> gray ->
r_rdy -> flush -> r_en -> consume_ptr loop that capped capture_clk.
Replaced the r_rdy-based "drain until empty" flush with a fixed-length
drain counter (FIFO is only tx_depth deep), removing the pointer
feedback from r_en. Path 24.3 -> 19.6 ns; flush behavior preserved.
- bba_top.py: wire shell <-> W5100 UDP (send + rx); shell additive.
- synth.py: shell default build; env-var UDP network config; documents a
reverted PNR-timing-priority experiment.
Timing (--seeds 8, default shell build, 67% LC): capture closes on 4/8
seeds (best seed 4 = 58.36 MHz, +8%), clk passes on all. This is BETTER
than the pre-shell 2/8 baseline because the flush fix improved the
capture domain intrinsically. Flash build/seed4/top.bin.
Bring-up caveats (unchanged): W5100 socket register addresses / UDP
header format are datasheet-derived (confirm on hardware); UDP_SRC_IP /
subnet / gateway must match the LAN for unicast ARP.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>