Roflin 6ce7657f05 eFuse V2.1 fix: datasheet-derived OVLO ladder + ILIM correction
Works the TPS25961 fix out from the datasheet rather than from memory, and
re-solves it against resistors already on the BOM.

OVLO: TI's 3-resistor ladder (eq 7/8) -> R46 620k->150k, R47 100k->10k, new
R48 12k + R49 2.2k (=14.2k).  UVLO 8.93 V typ, unchanged from today; OVLO
15.21 V typ, 15.81 V worst case.  The OVLO ceiling is set by U3 (TPS562201,
4.5-17 V input), not by the eFuse -- that rules out a tempting 3-resistor
solution tripping at 17.24 V.

ILIM: R45 100k -> 33k.  0.516 A sat BELOW the board's own 621 mA inrush, so
the part entered current limiting on every power-on (-> thermal shutdown ->
retries -> latch-off).  Inrush control comes from the fixed 5.17 V/ms slew
rate, not ILIM, so raising ILIM costs no inrush protection; it is pure fault
protection at ~27x the measured 56 mA load.

Every value is already stocked and 620k loses its only user: one FEWER unique
part, +2 placements.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>