Roflin b3685237b2 Support BOTH command-space forms: Swiss's 4-byte and libogc's 2-byte
Reading Swiss's own driver (cube/patches/bba/bba.c) shows the previous commit
fixed libogc and BROKE Swiss.  The two disagree, and both are real:

  Swiss   bba_cmd_out8: exi_imm_read_write(0x40<<24 | reg<<24 | val, 4)
          -> ONE 4-byte transfer [0x40|reg, 00, 00, val], and bba_cmd_in8
             returns the LOW byte, so a read response must be in BYTE 3.
  libogc2 bba_cmd_outsnosel: req = (reg<<8)|0x4000;
          EXI_ImmEx(&req, 2, WRITE); EXI_ImmEx(val, len, WRITE)
          -> THREE bytes, value in byte 2, and a read takes byte 2.
  stock libogc: identical to libogc2 (read out of libbba.a).

They share bytes 0 and 1 and differ only in how many bytes follow, so one
decoder serves both: take the LAST data byte before CS rise as the write value
(Swiss sends [00, val], libogc sends [val] -- last is val either way), and push
a read response TWICE so bytes 2 and 3 both carry it.  Swiss clocks 4 bytes and
pops both; libogc clocks 3 and leaves one, which the next transaction's header
pops drain -- a 2-byte header gives exactly one drain slot, so the leftover is
bounded at one and cannot accumulate.

Critically this means NO auto-increment of cmd_reg across the data phase: that
applied Swiss's padding 00 to the register and val to reg+1, which is precisely
how the libogc-only version broke Swiss.

T12 covers the Swiss form and asserts bytes 2 AND 3; T10 keeps the libogc form.
Both mutation-tested: re-adding the auto-increment fails T12 with 0x00 in both
slots, and pushing the response once fails T12's byte 3.  gc_bba_test gains
"cmd-space Swiss" alongside "cmd-space write", with bba_cmd_write4/read4.

Also corrects two things in CLAUDE.md now checkable against three drivers:
- NO driver writes TWD -- not Swiss, not libogc, not libogc2.  The "GC sets
  TWD before streaming" note was self-confirming: t_tx writes TWD because we
  wrote t_tx.  The counted TXDATA length is the primary path, not a fallback.
- Swiss's exi_dma_write rounds the length UP to 32 bytes (OSRoundUp32B), so
  TXDATA gets up to 31 trailing bytes past the frame and a counted length sends
  that much extra.  Real hardware must do the same since Swiss works on it;
  trailing padding past the IP total length is ignored.  A 1514-byte frame
  rounds to 1536 though, over the 1518 maximum.

Both drivers trigger TX with NCRA ST1, which the existing any-ST test accepts.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-10-10 11:01:33 +02:00
2026-06-13 19:02:58 +02:00
2026-08-28 10:29:41 +02:00
2026-06-16 14:59:18 +02:00
2026-08-28 10:29:41 +02:00
S
Description
No description provided
60 MiB
Languages
Python 84.9%
C 12.4%
Shell 1.1%
Dockerfile 0.7%
Makefile 0.4%
Other 0.5%