Files
rebbarb/hardware/re-bba-rb
Roflin a72e4ab1d4 docs: correct stale 'part fields blank' notes + flag kicad-cli zone-refill DRC trap
All eFuse/RExt/EE-CS parts (U13, R43-R47, C66, R44, D13) are picked with
MPN+LCSC in the live BOM and placed+routed on the PCB - the TODO/REVIEW
notes calling their fields 'intentionally blank' were written when the
parts were first added and never updated. Corrected to reflect the
committed state.

Also documents the kicad-cli DRC gotcha that caused a false alarm: it
does not refill zones, so it reports phantom GND-via-in-3V3-pour and
thermal-pad clearance errors (actual 0.000mm) on a board the GUI reports
clean. Added a warning at the top of TODO and in REVIEW section 7 so no
future session mistakes it for a real defect.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-08-02 08:37:39 +00:00
..
2026-07-31 22:06:21 +02:00
2026-07-31 22:06:21 +02:00
2026-07-31 22:06:21 +02:00
2026-07-31 22:06:21 +02:00
2026-07-31 22:06:21 +02:00
2026-07-31 22:06:21 +02:00
2026-07-17 21:35:02 +02:00
2026-07-31 22:06:21 +02:00
2026-07-31 22:06:21 +02:00
2026-07-31 22:06:21 +02:00
2026-07-31 22:06:21 +02:00