Add REVIEW.md: complete hardware-review coverage record

Documents everything examined in the 2026-07-17/18 review - not just
findings but full coverage with verdicts, so future sessions know what
not to re-review: per-sheet verification against datasheets and the
WIZnet reference design, the settled look-wrong-but-correct list
(VPHY/VPLL on 3.3V, D4/D5 floating VBUS + flow-through, EN at 12V,
RSET 12.4k, no CT cap, DO/DI direction evidence), PCB/JLC/BOM audit
state, explicit not-reviewed list (bench/gateware items), and a binding
rule to keep the file updated in the same commit as any change to a
reviewed circuit. Referenced from CLAUDE.md alongside TODO.md.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
2026-07-19 07:02:30 +00:00
committed by Dennis Brentjes
parent d0426b38fe
commit a86aa255f1
9 changed files with 10118 additions and 3936 deletions
+1 -1
View File
@@ -956,7 +956,7 @@
"uuid": "dbb182a6-d579-468e-b98b-6f0950da9e3a"
}
],
"used_designators": "R20-21,#PWR44-50,#PWR090e1-3,C17",
"used_designators": "",
"variants": []
},
"sheets": [