The docs call this 'Mode 3 (CPOL=1, CPHA=1)' and then describe sampling MOSI
on the FALLING edge. Idle-high plus sample-on-falling is Mode 2. Real Mode 3
samples on the second edge of each cycle, which with an idle-high clock is the
RISING one, and that is what the GameCube does.
Sampling on the same edge the GC drives MOSI latched the PREVIOUS bit, so
every byte arrived one bit late in both directions, at every clock speed:
the 0x80 register-space header byte was read as 0x00, which decodes as a
command-space device-ID query -- so NWAYS reads returned the device ID and the
speed sweep failed at every index. Hardware raw dump, first transaction after
an FPGA reset:
00 00 02 01 01 00 00 00 02 01 01 00 = 04 02 02 00 >> 1
The Pi probe never caught it because that script was written to match this
device, and every simulation testbench drives MOSI many capture ticks before
toggling the clock, so MOSI is stable at BOTH edges and the convention cannot
be distinguished. The bba_top master now models a true Mode 3 master (drive
on falling, sample on rising) so the suite can tell the difference.
SPIMode3Slave(mode2=True) restores the old behaviour for the Pi/J4 probe.
Known remaining issue: at EXI_HALF=1 (27 MHz, 2x oversampling) reads are still
shifted, because the 2-stage input FFSynchronizer costs 2 capture ticks which
at 27 MHz is a whole bit. That is a separate fault and only bites at 2x.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
bba_top derived its EXI clock from HALF, defaulting to 3.4 MHz against the
real GC's ~27 MHz. At that rate the whole CDC response latency fits inside
one bit time, so the suite passed green on a design that failed on console --
this is how both the wrong-header-format and the TX-pop-threshold bugs
reached hardware with everything green.
HALF is now EXI_HALF-configurable (default 8 for fast regression). At the
real rate, EXI_HALF=1, every read comes back shifted right by ONE BIT:
04 02 02 00 -> 02 01 01 00, NWAYS 0x17 -> 0x0B. That is a bit-level sampling
misalignment, not the byte-level latency chased earlier: at 54 MHz capture
there are only 2 ticks per EXI bit and the 2-stage FFSynchronizer on EXI CLK
costs 2 ticks, a whole bit.
Recorded as an open bug in CLAUDE.md with the measurements.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Replaces the invented 2-byte header (addr split across both bytes, 2-bit
length field) with the protocol libogc and Swiss actually speak:
command (bit7=0, 6-bit reg) [reg, 00, 00, data] one 4-byte transfer
register (bit7=1, 16-bit reg) [0x80|w<<6, ah, al, 00] + data until CS
This was not an optimisation: the old decoder read Swiss's NWAYS read
(80 00 31 00) as 'write 0x31 to NCRA', and bit 0 of 0x31 is RESET, so every
register read would have reset the device.
Changes:
* 16-bit address; no length field -- register reads and writes now stream
until CS, like the SPRAM path already did
* RHDR_LO starts the SPRAM fetch as soon as the address completes, using
the trailing header byte as the prefetch window the protocol provides
* command space serves EXI regs 0x02/0x03 (interrupt mask/status), the only
two Swiss uses
* EXI_GetID gets its own path: it offers just ONE header byte of warning, so
the first ID byte is pushed the instant byte 0 identifies the query
Two timing subtleties, both found by simulation and commented in place:
* MISO is driven LIVE from the tx FIFO head, so a byte pushed while the pad
byte is on the wire appears in the pad slot. A filler byte is parked
there (MISO is don't-care through the header) so the first real response
lands in data slot 0.
* the prefetch must be one-shot; re-firing while waiting for the pad byte
consumed the register stream early and shifted reads by a byte.
All testbenches updated to the real format and passing: bba_register_file
(7), bba_top (8 incl. the full W5100->SPRAM->GC loop and TX), exi_j4,
exi_capture, spi_mode3_slave, tx_frame_drain, spram_arbiter,
rx_frame_assembler, w5100_parallel_master. gc_bba_test rebuilt against the
new protocol.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
The init does MR=0x80 (software reset) then waits reset_cycles before writing
NETLCKR/SHAR/SIPR/socket registers. That wait was 24_000 cycles = 1 ms at
24 MHz, but the W5100S needs the datasheet's 60.3 ms -- our own bus self-test
needed ~85 ms before the chip answered at all.
1 ms is marginal rather than simply wrong, which is why this presented as
intermittent: an NCRA reset sometimes left the chip still resetting while the
init writes landed on it and were silently dropped, leaving it misconfigured
and the bus master blocked. Symptom was a W5100 that wedged after an NCRA
reset -- TX never completing and the UART shell's own 'udp unicast' hanging --
recoverable only by a 12 V power cycle. Note RST_N is never asserted by the
gateware; only the software reset is used, so this wait is the only settle
time the chip gets.
Default is now 2_000_000 = 83 ms. Testbenches pass small values explicitly and
are unaffected.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
TXFrameDrain sat in IDLE until it had a length, and the length only reached
tx_ctrl when the NCRA ST bits were written -- after the GC had streamed the
whole frame. So the entire frame had to fit in the 16-deep tx_bytes FIFO, and
BBARegisterFile silently drops bytes when w_rdy is low (SPI cannot
back-pressure). On hardware this truncated frames at exactly 16 bytes: a
captured ARP had 16 correct bytes followed by the frame restarting over itself.
The length is now handed to the drain one cycle after the TWD_HI (0x35) write,
which the GC issues BEFORE streaming data. The drain starts early and blocks
on tx_bytes_r_rdy, consuming bytes as they arrive, so tx_bytes becomes a
rate-matching buffer instead of whole-frame storage. The ST write remains a
fallback trigger for software that skips TWD, guarded by tx_queued so one frame
is never queued twice.
Adds BBATop T8: streams a 34-byte frame (> the 16-deep FIFO) over EXI and
checks the W5100 model received it byte-for-byte. Verified to FAIL without the
fix with exactly the hardware symptom -- 16/34 bytes, first bad byte at index
16. The gap that let this ship: TXFrameDrain's own tests drive the FIFO
signals directly, and the BBATop test only covered the RX loop.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Reverts the 0x8000/0xC000 change from 162dbf7, which was WRONG and actively
broke transmission. The W5100S datasheet pseudo-code quotes 0x8000 (TX) /
0xC000 (RX) for the memory blocks, but the PARALLEL/indirect (IDM) interface
only decodes a 15-bit offset. Bench-proven with an address-aliasing probe:
writing distinct values to each candidate base and reading them back showed
0xC000 and 0x4000 are the SAME cell (0xC000 & 0x7FFF == 0x4000) while 0x6000
holds its own value.
Consequence of the bad base: every payload byte written to 0x9800+i aliased
down onto 0x0000+i, landing on SHAR (0x09-0x0E) and SIPR (0x0F-0x12) and
overwriting them with the payload. The chip then transmitted frames with a
garbage source MAC/IP, which the peer NIC drops without counting -- the
"SEND_OK but rx_packets=0" symptom, and the bogus SIPR0 readback (0x50 was
literally payload byte 15, 'P').
The NETLCKR unlock from 9c4bc7a is a genuine W5100S requirement and stays.
Also:
- w5100_udptest.py: self-contained configure+send+readback probe (and the
address-aliasing probe that found this), reports over UART.
- scripts/build-flash.sh: sweep N seeds and flash the best (capture timing is
seed-dependent, so the sweep is mandatory).
- scripts/uart-console.py: interactive UART console, plus --send/--read
one-shot modes for scripting.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Second W5100S-vs-W5100 gotcha found at bring-up: the W5100S has a Network Lock
Register (NETLCKR, 0x0071) the original W5100 lacks. It defaults to 0x00 (locked),
and while locked, ALL writes to GWR/SUBR/SHAR/SIPR are silently dropped -- so the
chip has no source IP/MAC and the UDP/MACRAW send builds nothing (chip reports
SEND_OK but transmits nothing; socket registers aren't locked, which is why an
indirect write/readback of Sn_PORT succeeded). Fix: write the unlock value 0x3A
to NETLCKR right after MR enables indirect mode, before the network-config writes.
On the bench this flipped the board from silent to actually keying frames onto
the wire (magjack activity LED now blinks).
Also:
- bba_top.py test model: RX buffer base 0x6000 -> 0xC000 to match the W5100S
buffer-base fix (the model hardcoded the old W5100 address).
- w5100_selftest.py: added an indirect-mode (IDM) write/readback probe of a
socket register + IND= field in the UART report, to isolate direct-vs-indirect
access (confirmed indirect works on the real chip).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
An interactive UART command shell drives a UDP send/receive test on the
W5100's socket 3, running ALONGSIDE the live BBA (socket-0 MACRAW) with
EXI keeping bus priority. MACRAW+UDP coexistence is W5100S-datasheet
confirmed (S4.6 + "4 independent SOCKETs"). Now the default flash build
(--console selects the old event-log console).
New / changed gateware:
- uart_shell.py (new): rebbarb> shell over FT2232H channel B. Commands:
help; udp unicast <ip> [msg]; udp broadcast [msg]. After each send it
waits (bounded, else "timeout") for a reply and prints "rx <payload>".
Line buffer + message ROM live in block RAM with a sequential parser
(LC-efficient); 1-deep RX holding reg keeps pastes intact. 8 sim tests.
- w5100_parallel_master.py: configurable UDP socket (default 3) with UDP
send AND receive (IP-stack init, runtime dest IP, WIZnet UDP RX header
+ payload). Gated by enable_udp_test so the MACRAW path is unchanged
when off. Tests U1-U4 + MACRAW T1-T5.
- exi_capture.py: CAPTURE-DOMAIN CRITICAL-PATH FIX. The TX byte-FIFO
read-enable was gated by its own gray-coded ready
(r_en = ... | (flushing & r_rdy)), forming a consume_ptr -> gray ->
r_rdy -> flush -> r_en -> consume_ptr loop that capped capture_clk.
Replaced the r_rdy-based "drain until empty" flush with a fixed-length
drain counter (FIFO is only tx_depth deep), removing the pointer
feedback from r_en. Path 24.3 -> 19.6 ns; flush behavior preserved.
- bba_top.py: wire shell <-> W5100 UDP (send + rx); shell additive.
- synth.py: shell default build; env-var UDP network config; documents a
reverted PNR-timing-priority experiment.
Timing (--seeds 8, default shell build, 67% LC): capture closes on 4/8
seeds (best seed 4 = 58.36 MHz, +8%), clk passes on all. This is BETTER
than the pre-shell 2/8 baseline because the flush fix improved the
capture domain intrinsically. Flash build/seed4/top.bin.
Bring-up caveats (unchanged): W5100 socket register addresses / UDP
header format are datasheet-derived (confirm on hardware); UDP_SRC_IP /
subnet / gateway must match the LAN for unicast ARP.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>