f3fee5667319b9a2badc37d67f6e639d2e842fc3
12 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
90a583dd46 |
Remove the device-ID one-shot: it made Swiss see no adapter at all
id_phase was set at reset and cleared permanently by the GC's first NCRA reset, after which a command-space read of register 0 returned 0x00000000. Swiss calls EXI_GetID from bba_exists() AND again from bba_requires_init(), long after init, and matches the result against EXI_MX98730EC_ID -- so with the one-shot spent no case matched and Swiss reported NO ADAPTER, not a broken one. Running gc_bba_test was enough to spend it, so the adapter would "disappear" after any test session. The justification in the comment was wrong. It claimed the fast path would otherwise hijack address 0 so the GC could never read NCRA back -- but NCRA is REGISTER space (0x80/0xC0 header) while the fast path requires byte 0 == 0x00, i.e. COMMAND space. They were never ambiguous, and no driver reads command register 0 for anything else (libogc2 reads 0x01/0x03/0x0B/0x0F, Swiss 0x03). Real hardware answers EXI_GetID whenever asked; that is how EXI enumerates devices. id_arm is now tied high, and the id_phase output, the FFSynchronizer that crossed it into the pin domain, and the BBATop wiring are all gone. The port stays only so the PHASE_METER build can disarm the fast path, which would otherwise send ID bytes instead of its constant 0x80. bba_top T1b reads the device ID AFTER an NCRA reset, which T1 (before any reset) structurally cannot catch. Mutation-tested: disarming the fast path returns 00 00 00 00 for both, exactly what Swiss saw. gc_bba_test: the ID tests no longer skip. A wrong ID is a FAILURE again, with no iface_alive() discrimination and no ordering requirement between suites -- the ID is readable at any point in a run. g_ncra_reset_done and iface_alive() are removed outright rather than left as a dead flag. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |
||
|
|
7587636b48 |
Answer the device-ID query from the bit engine, not the register file
bba_devid fails on a console with 00 04 02 02 -- the ID correct but one byte
late -- and it fails in its REAL shape, with the 16 us gap and exactly four
bytes clocked, so this is not the t_raw_id probe artefact. The register suite
passes, so register-space reads are fine; only command space is affected.
Cause is latency, not phase. A command-space header is two bytes, so the
reply must be in the tx FIFO by the LAST RISING EDGE of the header transfer:
one byte time, 296 ns at 27 MHz. The round trip is rx AsyncFIFO (~125 ns) +
a sync cycle + tx AsyncFIFO (~110 ns) = 280-320 ns, marginal by construction.
HEADER0 already pushed in the same cycle it consumed byte 0, so the FSM side
was already as early as it can be.
The inter-transfer gap cannot rescue it: the load happens on that last rising
edge and the clock is PAUSED afterwards, so no edge exists during the gap for
anything to update. That is why bba_devid's 16 us gap makes no difference.
Pre-pushing the ID at CS-fall does not work either -- the engine's
unconditional per-byte pops would eat it, and the header length is not known
until byte 0 has been decoded, which is the latency in question.
So take the round trip out of the path. The device ID is a hardwired constant
and belongs to the physical interface rather than to the register file, and
byte 0 == 0x00 identifies the query exactly (bit 7 clear = command space, bit
6 clear = read, reg 0). SPIMode3Slave now recognises it and answers
04 02 02 00 from the EXI clock domain, with no CDC at all. The only thing it
needs from sync is id_phase, a single bit that changes once, crossed with an
FFSynchronizer.
The register file's ID path is REMOVED rather than kept as a fallback: left
in, it would push bytes that a 2-byte header has too few pops to drain, which
is exactly how an earlier version made the NEXT enumeration come back a slot
late.
Tests follow the responsibility:
- spi_mode3_slave T7: the query returns 04 02 02 00 with the tx FIFO
deliberately feeding 0x00, so only the fast path can be answering.
- spi_mode3_slave T8: and it is GATED -- with id_arm low, 0x5A comes
through from the FIFO. Without this the fast path would hijack address 0
forever and the GC could never read NCRA back after its own reset.
- bba_register_file T1: retargeted to assert the FSM pushes NOTHING for an
ID query, which is the property that stops stale bytes corrupting the
following transaction.
Note what these tests do NOT establish: bba_top already passed the device ID
at EXI_HALF=1 before this change, because simulation cannot reproduce a
296 ns window miss -- the sync domain's latency relative to the EXI clock in
sim does not match silicon closely enough. T7/T8 prove the fast path works;
the evidence that it is NECESSARY is the hardware result plus the paused-clock
argument above.
--seeds 8: clk 28.4-31.0 MHz, EXI 56.7-64.4 MHz, 8/8 PASS. Best seed 2
(clk 30.98, EXI 59.47), flashed.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
|
||
|
|
7ac0cbe66c |
Launch MISO a full cycle early instead of chasing delay
PHASE_METER on a console settled what two rounds of delay-cutting could not.
Per-speed dump, first two slots per EXI speed index, with the register file
and both byte FIFOs out of the MISO path:
0:8080 1:8080 2:8080 3:8080 4:8080 5:C040
Perfect to 16 MHz, one bit late at 27 MHz. The 8-slot dump at 27 MHz read
C0 40 40 40 C0 40 40 40 -- a UNIFORM one-bit lag (ones at bits 1, 9, 17, 25,
33, ...), with extra highs at bits 0 and 32 where libogc splits the read into
two 4-byte transfers and MISO tri-states to its pull-up in the gap. The ID
dump agreed exactly.
Decisive detail: ~9 ns had already been removed from the fabric output path
(the EXI_J4 pad merge, then the CS mux, then the entire fabric route by moving
the output into an SB_IO register) and the hardware result stayed BYTE
IDENTICAL each time. Nine nanoseconds out of an 18.5 ns budget cannot change
nothing if propagation were the whole story. What is left is the part no RTL
change can reach: input pad + GLOBAL CLOCK NETWORK INSERTION + IOB clock-to-Q
+ output pad, plus the host's own setup. There was no fabric delay left to
cut, so cutting delay was the wrong move.
So double the budget instead. MISO is now launched on the RISING edge
carrying the bit the host will sample at the NEXT rising edge, so the whole
path gets a FULL period (37 ns at 27 MHz) rather than half. This is safe in
both directions: the insertion delay that caused the problem now covers the
host's hold time on the previous bit, and a full period covers its setup.
- tx_out is clocked on the rising edge and loads at rx_bit == 7, one
bit-time earlier than a falling-edge shifter loading at rx_bit == 0.
- tx_hold and the entire exiclk_n domain are gone: the engine now has ONE
clock edge and ONE phase reference.
- synth.py's SB_IO output register moves to NEG_TRIGGER=0.
- Byte alignment is unchanged -- T2/T5 still land A5 and 3C in the same
slots. Only the sub-bit launch timing moved.
Testbench consequence, and it matters: bba_top's master sampled MISO AFTER
raising the clock. With a zero-delay simulation and a rising-edge launch that
reads the NEXT bit, so the suite would have reported everything one bit early
while hardware was correct. Both masters now sample in the CLK-LOW phase --
the value the host latches ON the rising edge -- which is also exactly what
the hardware notes say a probe must do.
T2 slot 0 now reads 0xFF (the CS-reset parking value that keeps MISO high
while deselected) instead of 0x00; it is a header byte the host ignores.
T6 re-anchored to the rising edge and still proves miso_next predicts
spi_miso bit for bit, so the SB_IO register stays equivalent to the fabric
model rather than an untested divergence.
--seeds 8: clk 28.9-32.1 MHz, EXI 62.1-65.4 MHz, 8/8 PASS. The EXI numbers
rise sharply (41.6-49.7 -> 62.1-65.4) because the setup path into the IOB
register is now posedge->posedge against a FULL period instead of
posedge->negedge against a half -- the same doubling, visible internally.
Best seed 3 (clk 32.09, EXI 62.78), flashed.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
|
||
|
|
2f081a3e69 |
Drive MISO from an SB_IO output register
Removing ~2 ns from the fabric MISO path (EXI_J4 merge + the CS mux) did NOT move the hardware result: the GC still returned a byte-identical 0B 80 at 27 MHz while reading correctly at 16 MHz and below. Identical rather than intermittent means the path is well outside the window, not marginally inside it, so trimming fabric delay further was not going to get there. MISO is source-synchronous -- driven on the falling edge, sampled by the GC on the next rising edge -- so the whole path must fit a HALF period, 18.5 ns at 27 MHz, minus global-buffer insertion, pad, connector and the GC's setup. Driving from fabric spent 8.4-11.5 ns of that on routing alone. An SB_IO output register sits in the IO tile: clock-to-pad is the IO flop's own delay with no fabric routing. nextpnr confirms the path left the fabric entirely -- miso_io.D_OUT_0 packs at die (9,0), the pad itself, SB_IO count is unchanged at 24, and no negedge -> <async> path is reported any more. What replaces it is a setup path INTO the IOB register (10.07 ns against a half-period), which is internal and has nothing stacked on top of it. PIN_TYPE was decoded from yosys's own SB_IO model rather than from memory, because wrong bits there produce a silently dead or mistimed output: [5:4]=10 tri-state, combinational OUTPUT_ENABLE [3]=0,[2]=1 dout = dout_q_0, single-rate REGISTERED output [1:0]=01 simple input (unused) NEG_TRIGGER=1 moves the IO registers to the FALLING edge. To keep simulation and silicon agreeing about MISO, the slave exposes miso_next -- the value the shift register WILL hold after the falling edge -- and spi_mode3_slave T6 proves it predicts spi_miso bit for bit. Without that the IOB register would be an untested sim/hardware divergence, which is the exact class of bug that has cost this design the most time. BEHAVIOUR CHANGE: MISO is now TRI-STATED when CS is high, held high by the pad's PULLUP, instead of actively driven high. EXI MISO is a SHARED bus -- SP1 is on channel 0 alongside memory-card slot A -- so driving it while deselected was wrong and could fight a card. --seeds 8: clk 28.5-30.7 MHz, EXI 41.6-49.7 MHz, 8/8 PASS. The EXI numbers fall (62 -> 49) because the posedge->negedge setup path into the IOB register is now charged to that domain at a half-period constraint; 41.6 MHz worst case is still 1.5x the 27 MHz target. Best seed 3 (clk 30.68, EXI 49.14), flashed. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |
||
|
|
d35688390e |
Take the TX bit phase from the rising-edge counter, not a falling-edge one
The bit engine had TWO independent phase references: rx_bit counting rising
edges and tx_bit counting falling edges. Those only stay in step while the
host emits exactly as many falls as rises, and it does not -- a transfer that
begins on a RISING edge (CS asserted while CLK is already low, or the clock
gating between two back-to-back host transfers) delivers a rise with no
matching fall. tx_bit then slips one bit and never recovers.
RX never notices, because the rising count always equals the host's bit count.
So the header decodes perfectly, the right register is selected, and ONLY MISO
is wrong -- which is what made this look like an output-edge or output-delay
problem for two rounds of debugging.
Measured on a GameCube: every MISO byte shifted right by 2 bits, identically
at every EXI speed index. NWAYS read 05 C0 (= 0x17 with two leading zero
bits), device ID 01 00 80 80, speed sweep ok=[0,0,0,0,0,0].
Two diagnoses were wrong before this one, and both were ruled out by evidence
rather than argument:
- NOT propagation delay. Index 0 is 1 MHz, a 1000 ns bit time; no output
path fails there. Speed-independence is the tell.
- NOT the output edge. The old rising-edge build and the new falling-edge
build returned BYTE-IDENTICAL 05 C0. Flipping the edge would have moved
it; it did not, so the slip is upstream of the output stage.
What settled it was a measurement. PHASE_METER=1 builds a diagnostic,
non-functional bitstream whose engine transmits a constant 0x80 per byte
instead of the FIFO head, taking the register file and both byte FIFOs out of
the MISO path so the host reads the engine's byte PHASE directly: 0x80
aligned, 0x40 one bit late, 0x20 two bits late. Hardware read 0x20 in all
eight slots, localising the fault to the bit engine in a single run.
Fix: the shift register loads on rx_bit == 0. One phase reference, on the
edge the host counts, so the two cannot drift.
Regression test (spi_mode3_slave T5) asserts CS while CLK is LOW so the
transaction begins on a rising edge. The old counter fails it by exactly one
bit: A5 3C comes back as 52 9E. EVERY earlier testbench asserted CS with CLK
high, so falls and rises always matched and the slip was structurally
invisible -- the same blind spot as the Mode 2/3 mix-up, which was invisible
to a master that parked MOSI early. Vary the starting edge in SPI tests.
Timing after the fix, EXI_J4=1, --seeds 8: clk 26.9-31.1 MHz, EXI 45.8-61.7
MHz, 8/8 PASS. Best seed 4 (clk 31.07, EXI 56.70), flashed.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
|
||
|
|
91c3bf0ece |
Clock the EXI bit engine from the EXI pin: timing closes on all 8 seeds
Replaces the PLL-fed 54 MHz `capture` domain, which oversampled the GC's
27 MHz EXI clock 2x and so put BIT-level timing across a CDC boundary: the
engine's view of the clock lagged the pin by 2 FFSynchronizer stages plus a
register (~55 ns) against a 37 ns bit time, so MISO came out ~2 bits late and
the GC read 0x17 as 05 C0. No amount of oversampling fixes that -- 54 MHz
gives only 2 ticks per bit and the part cannot close the 81 MHz that 3x needs.
The engine is now clocked by the pin itself (pin 44 = global buffer input net
6, no board change), making MISO clock-to-Q. ExiCapture creates four domains:
exiclk (posedge, samples MOSI), exiclk_n (negedge, drives MISO), both
async-reset by CS, plus reset-less exififo_w/exififo_r for the byte FIFO sides
-- reset-less because resetting one side of an AsyncFIFO desynchronises its
gray pointers, and posedge because AsyncFIFO has a posedge-only reset CDC
internally and cannot host a negedge side.
Also removes the SPRAM response FIFO. The DMA read was one byte late because
the round trip did not fit the protocol's turnaround byte; the arbiter already
exposed valid/ready, so the FIFO bought a cycle of latency and nothing else.
The response is handled outside the FSM (the reply lands in RHDR_PAD, not
SPRAM_STREAM) with a one-entry hold for when tx_fifo is momentarily full.
The PLL was left instantiated but unused after the rewrite; removing it frees
the hard macro and pin 35 (which stays unconnected only because the board is
already built that way). This is what lifted the pass rate:
domain target before after
clk (sync) 24 MHz 28.1-30.2 26.4-32.2 8/8
capture_clk 54 MHz 2 of 8 PASS (gone)
EXI pin domain 27 MHz -- 45.6-64.4 8/8
Best seed 3: clk 32.18 MHz, EXI 55.86 MHz. The binding constraint has FLIPPED
-- `clk` (1.10-1.34x) is now tighter than the EXI domain (1.69-2.39x) -- so
synth.py ranks seeds by worst RELATIVE margin, not by the EXI number.
synth.py could not have scored this design at all: it required the vanished
capture_clk, and its regex '(\w+)' cannot match nextpnr's exi_clk_$glb_clk
(no $ in \w). add_clock_constraint was also landing on the wrong net -- under
EXI_J4 the clock is the AND of two pads, not either pad -- so nextpnr silently
fell back to a 12 MHz default and under-optimised the whole EXI domain.
Testbenches:
- spi_mode3_slave had lost its testbench entirely in the rewrite. Restored
with a strict Mode 3 master (changes MOSI on the falling edge, samples MISO
in the clock-low phase) and MUTATION-TESTED: flipping either clock edge in
the RTL makes it fail. Both of those bugs previously reached silicon
against a lax master that parked MOSI well before the edge.
- exi_j4 T2/T3 returned [0,4,2,2]. Real bug: the engine latches the FIFO head
at each byte boundary, so a 2-byte command header leaves only ONE drain
slot. DEVID streamed zeros until CS and left two stale bytes -- one too
many -- so the NEXT enumeration came back a slot late. DEVID now pushes
exactly four bytes and stops. Register-space reads may still over-push:
their 4-byte header gives three drain slots.
- Dead ports removed from SPIMode3Slave (hdr_bytes, frame_start, cs_active,
byte_idx) and the mode2 parameter is gone -- there is one correct edge
convention and it is now enforced by tests.
All 14 module suites pass, plus bba_top at EXI_HALF=1/2/8.
CLAUDE.md: rewrote the clocking, CDC inventory and module tables; marked the
2026-09-30 capture_clk measurements historical; and corrected the line in
"Critical Protocol Notes" that still stated the INVERTED edge convention
("MOSI sampled on falling, MISO driven on rising" is Mode 2) -- the original
implementation followed that doc error.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
|
||
|
|
02239466fb |
Merge the exi and sync domains into one
bba_top wired ClockSignal("sync") to ClockSignal("exi"), so the two "domains"
were always the same physical clock net. Everything between them -- six
AsyncFIFOs and three PulseSynchronizers -- was pure latency and logic for a
crossing that did not exist.
* the six AsyncFIFOs become plain SyncFIFOs
* the three PulseSynchronizers become wires
* BBARegisterFile and ExiCapture move from m.d.exi to m.d.sync
* the exi ClockDomain is gone; HFOSC drives sync directly
The SPRAM request write port is also combinational now. A registered w_en
costs a 24 MHz cycle, and the protocol's turnaround byte (~296 ns at 27 MHz)
has no cycles to spare.
Passing: bba_register_file, spram_arbiter, rx_frame_assembler, tx_frame_drain,
w5100_parallel_master, uart_shell, status_panel. bba_top at EXI_HALF=1
(27 MHz, the hardware rate) passes device ID, PAR read/write, NWAYS, RWP and
the 34-byte TX frame.
STILL OPEN: the SPRAM/DMA read is one byte late. Removing the CDC was not
enough -- the remaining round trip is the rx crossing (exiclk->sync, a REAL
CDC, ~125 ns) plus FSM decode plus the spram_req FIFO, arbiter, SPRAM access
and spram_rsp FIFO, which still exceeds the turnaround byte. Next step: now
that it is all one domain, drop the two SPRAM FIFOs entirely and give the
register file a direct request/grant port on the arbiter -- that should take
the round trip to ~2-3 cycles and fit.
exi_capture and exi_j4 testbenches still assert removed behaviour (the CS-fall
flush and the old MISO slot timing) and need rewriting for the clocked engine.
Still WIP -- do not flash.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
|
||
|
|
da21a080d9 |
TX passes at 27 MHz; remaining DMA offset traced to needless exi/sync CDC
The TX failure was a TESTBENCH artifact, not a design bug. Between
transactions the bench raised CS for one HP -- 18.5 ns at EXI_HALF=1 -- but
cs_active reaches the exi domain through a 2-stage FFSynchronizer at 24 MHz,
so the register file never saw one transaction end and swallowed the next
one's header as write data. A real host leaves microseconds between
exi_deselect() and the next exi_select(). With a realistic gap the 34-byte TX
frame now matches byte-for-byte at the hardware rate.
At EXI_HALF=1 (27 MHz) bba_top now passes device ID, PAR read/write, NWAYS,
RWP and TX. The one remaining failure is the SPRAM/DMA stream, offset by
exactly one byte.
Root cause of that offset, and it is not architectural: bba_top.py:171 does
m.d.comb += ClockSignal("sync").eq(ClockSignal("exi"))
so exi and sync are LITERALLY THE SAME CLOCK NET. Every AsyncFIFO between
them is pure overhead. The SPRAM round trip pays two needless CDC crossings
(~6 cycles, ~250 ns) on top of the arbiter and SPRAM access, giving ~375 ns
against the ~170 ns the protocol's turnaround byte actually leaves once the rx
crossing is subtracted. Register reads are unaffected because their response
is immediate; only SPRAM is late.
Fix direction: merge the two domains and replace the exi<->sync AsyncFIFOs and
PulseSynchronizers with plain SyncFIFOs/signals. That removes the latency,
drops a lot of logic, and cannot change behaviour because the clocks are
already identical.
Known failing, both testing removed behaviour rather than new bugs:
* exi_capture's own testbench asserts the CS-fall flush and the old MISO
slot timing; the flush no longer exists (header pops drain the FIFO).
* exi_j4's T3 re-enumerate is off by a byte.
Still WIP -- do not flash.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
|
||
|
|
a3b3e052bc |
WIP rewrite: clock the EXI bit engine from the EXI clock pin
Replaces 54 MHz oversampling with a slave clocked by EXI CLK itself:
exiclk posedge sample MOSI (Mode 3 samples on edge 2)
exiclk_n negedge drive MISO (must settle between the master's samples)
CS_N async reset for both
EXI CLK (pin 44) is at die (6,0) = global buffer net 6 on the 5k-sg48, so it
can drive a real clock network with no board change.
This removes the capture domain entirely. Bit-level timing no longer
crosses a clock boundary -- MISO is clock-to-Q instead of 3 ticks of a foreign
clock -- and the only crossings left are the byte FIFOs, which have a whole
byte-time (~296 ns) of slack rather than a fraction of a bit.
AsyncFIFO needs a posedge clock for its internal reset CDC, so the FIFO sides
use reset-less POSEDGE domains on the same pin; the engine pops on the posedge
and hands the byte to the negedge output stage through a register. The FIFOs
must not see CS: resetting one side of an AsyncFIFO desynchronises its gray
pointers.
Two bugs found and fixed along the way:
* one pop per byte boundary is all that is needed -- pops during the header
drain whatever the previous transaction left (replacing the CS-fall flush)
and the turnaround-byte push lands in data slot 0. No slot-threshold or
header-length logic at all.
* rx_byte/rx_valid had to become COMBINATIONAL. Registered, they need one
more clock edge, and after a transaction's final bit the clock stops and
CS rises -- so the last byte of every transaction was lost (a 4-byte write
landed as DE AD BE 00, a 34-byte TX as 15 bytes).
At the HARDWARE rate (EXI_HALF=1, 27 MHz) the device ID, NWAYS, PAR
read/write and the W5100->SPRAM RX path now all pass -- none of which has ever
worked at 27 MHz before. Testbenches now drive the SPI clock with real
delays, since there is no capture domain to count ticks against.
STILL BROKEN: the SPRAM/DMA stream is offset by one byte (its round trip
exceeds the single turnaround byte), and TX lands 15 of 34 bytes. Do not
flash this yet.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
|
||
|
|
399fbf02a4 |
fix(exi_capture): TX pop threshold must follow the header length
tx_fifo.r_en popped from txld_cnt >= 2, hard-coded for the old invented 2-byte header where the data phase began at slot 2. The real protocol's register space uses a 4-byte header, so data starts at slot 4 -- two bytes were being consumed before the GC clocked any data, and every register read came back wrong. On hardware: HIPR and NWAYS both read 0x00, and the device ID returned 01 80 c0 c0 (stale bytes, including our own header command bytes 0x80/0xC0 echoing back out of the FIFO). The threshold is now derived from byte 0 bit 7, which is exactly what selects the header form: register space -> 4 slots, command space -> 2 slots. Also removes the pad-slot filler byte the register file was pushing. That was compensating for this bug rather than fixing it -- it made the simulation pass while hardware still failed, which is how it slipped through. With the pop threshold correct the filler is wrong, and both the unit and integration testbenches agree without it. All suites pass: bba_register_file, bba_top, exi_capture, exi_j4, spi_mode3_slave, tx_frame_drain, spram_arbiter, rx_frame_assembler, w5100_parallel_master. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |
||
|
|
c16afb6eea |
Add integrated UART UDP bring-up shell (socket 3) + capture critical-path fix
An interactive UART command shell drives a UDP send/receive test on the W5100's socket 3, running ALONGSIDE the live BBA (socket-0 MACRAW) with EXI keeping bus priority. MACRAW+UDP coexistence is W5100S-datasheet confirmed (S4.6 + "4 independent SOCKETs"). Now the default flash build (--console selects the old event-log console). New / changed gateware: - uart_shell.py (new): rebbarb> shell over FT2232H channel B. Commands: help; udp unicast <ip> [msg]; udp broadcast [msg]. After each send it waits (bounded, else "timeout") for a reply and prints "rx <payload>". Line buffer + message ROM live in block RAM with a sequential parser (LC-efficient); 1-deep RX holding reg keeps pastes intact. 8 sim tests. - w5100_parallel_master.py: configurable UDP socket (default 3) with UDP send AND receive (IP-stack init, runtime dest IP, WIZnet UDP RX header + payload). Gated by enable_udp_test so the MACRAW path is unchanged when off. Tests U1-U4 + MACRAW T1-T5. - exi_capture.py: CAPTURE-DOMAIN CRITICAL-PATH FIX. The TX byte-FIFO read-enable was gated by its own gray-coded ready (r_en = ... | (flushing & r_rdy)), forming a consume_ptr -> gray -> r_rdy -> flush -> r_en -> consume_ptr loop that capped capture_clk. Replaced the r_rdy-based "drain until empty" flush with a fixed-length drain counter (FIFO is only tx_depth deep), removing the pointer feedback from r_en. Path 24.3 -> 19.6 ns; flush behavior preserved. - bba_top.py: wire shell <-> W5100 UDP (send + rx); shell additive. - synth.py: shell default build; env-var UDP network config; documents a reverted PNR-timing-priority experiment. Timing (--seeds 8, default shell build, 67% LC): capture closes on 4/8 seeds (best seed 4 = 58.36 MHz, +8%), clk passes on all. This is BETTER than the pre-shell 2/8 baseline because the flush fix improved the capture domain intrinsically. Flash build/seed4/top.bin. Bring-up caveats (unchanged): W5100 socket register addresses / UDP header format are datasheet-derived (confirm on hardware); UDP_SRC_IP / subnet / gateway must match the LAN for unicast ARP. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> |
||
|
|
8d0ab1d948 | Added full design created with Claude |